M1503.6.2 Makeup Air Dampers
JUMP TO FULL CODE CHAPTER
Where makeup air is required by Section M1503.6, makeup air dampers shall comply with this section. Each damper shall be a gravity damper or an electrically operated damper that automatically opens when the exhaust system operates. Dampers shall be located to allow access for inspection, service, repair and replacement without removing permanent construction or any other ducts not connected to the damper being inspected, serviced, repaired or replaced. Gravity or barometric dampers shall not be used in passive makeup air systems except where the dampers are rated to provide the design makeup airflow at a pressure differential of 0.01 in. w.c. (3 Pa) or less.
Related Code Sections
M1503.6.2 Exhaust Systems, Makeup Air Dampers
Where makeup air is required by Section M1503.6, makeup air dampers shall comply with this section. Each damper shall be a gravity damper ...
Residential Code 2018 of Kansas > 15 Exhaust Systems > M1503 Domestic Cooking Exhaust Equipment > M1503.6 Makeup Air Required > M1503.6.2 Makeup Air Dampers
2404.8.2 Flammable Finishes, Ventilation Interlock Prohibited
Air makeup and flammable vapor area exhaust systems shall not be interlocked with the fire alarm system and shall remain in operation during a fire ...
Fire Code 2018 of Kansas > 24 Flammable Finishes > 2404 Spray Finishing > 2404.8 Interlocks > 2404.8.2 Ventilation Interlock Prohibited
N1102.4.1.2 [RE] Energy Efficiency, (R402.4.1.2) Testing
Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures ...
Residential Code 2018 of Kansas > 11 [RE] Energy Efficiency > N1102 (R402) Building Thermal Envelope > N1102.4 (R402.4) Air Leakage (Mandatory) > N1102.4.1 (R402.4.1) Building Thermal Envelope > N1102.4.1.2 (R402.4.1.2) Testing
R402.4.1.2 [RE] Residential Energy Efficiency, Testing
including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures ...
Energy Conservation Code 2018 of Kansas > 4 [RE] Residential Energy Efficiency > R402 Building Thermal Envelope > R402.4 Air Leakage (Mandatory) > R402.4.1 Building Thermal Envelope > R402.4.1.2 Testing
1105.6.2 Refrigeration, Makeup Air
Provisions shall be made for makeup air to replace that being exhausted. Openings for makeup air shall be located to avoid intake of exhaust air ...
Mechanical Code 2018 of Kansas > 11 Refrigeration > 1105 Machinery Room, General Requirements > 1105.6 Ventilation > 1105.6.2 Makeup Air