• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[NY] 107.1 Maintenance of Required Safeguards

2020 Fire Code of NYS > 1 Scope and Administration > 107 Maintenance of Equipment and Systems > 107.1 Maintenance of Required Safeguards
JUMP TO FULL CODE CHAPTER
Where any device, equipment, system, condition, arrangement, level of protection, or any other feature is required for compliance with the provisions of this code, or otherwise installed, such device, equipment, system, condition, arrangement, level of protection, or other feature shall thereafter be continuously maintained in accordance with this code, the Property Maintenance Code of New York State and applicable referenced standards.

[NY] 107.1.1 Existing Nonrequired Safeguards

Wherever any nonrequired device, equipment, system, condition, arrangement, level of protection, or any other feature is provided, such device, equipment, system, condition, arrangement, level of protection, or other feature shall, thereafter, be continuously maintained in accordance with this code and applicable referenced standards or shall be removed in its entirety.

Exceptions:

  1. Nonrequired devices, equipment and systems are permitted to be removed in entirety;
  2. Nonrequired devices, equipment and systems are permitted to be disabled, provided that all visible elements are removed;
  3. Electrically charged devices, equipment and systems are permitted to be disabled, provided they are disconnected from power sources and all visible elements are labeled as not being energized; and
  4. Nonrequired fire protection systems are permitted to be disabled, provided that sprinkler heads, exposed valves, fire department connections, initiating and notification devices and similar equipment are removed, and any remaining visible components are labeled as not being in service.

Related Code Sections


106.1 Administration, Maintenance of Required Safeguards
Whenever or wherever any device, equipment, system, condition, arrangement, level of protection, or any other feature is required for compliance ...
2010 Fire Code of NY > 1 Administration > 106 Maintenance of Equipment and Systems > 106.1 Maintenance of Required Safeguards
107.1 Scope and Administration, Maintenance of Required Safeguards
Where any device, equipment, system, condition, arrangement, level of protection, or any other feature is required for compliance with the provisions ...
2020 Fire Code of NYS > 1 Scope and Administration > 107 Maintenance of Equipment and Systems > 107.1 Maintenance of Required Safeguards
M1202.3 Mechanical Administration, Maintenance
and in a safe and sanitary condition. Devices or safeguards that are required by this code shall be maintained in compliance with the code edition ...
2020 Residential Code of New York State > 12 Mechanical Administration > M1202 Existing Mechanical Systems > M1202.3 Maintenance
Section 101 General Requirements, Title, Scope and Purpose
requirements to safeguard public safety, health and general welfare insofar as they are affected by the occupancy and maintenance of structures ...
2010 Property Maintenance Code of NY > 1 General Requirements > 101 Title, Scope and Purpose
Section 3302 Safeguards During Construction, Construction Safeguards
Required exits , existing structural elements, fire protection devices and sanitary safeguards shall be maintained at all times during alterations ...
2020 Building Code of New York State > 33 Safeguards During Construction > 3302 Construction Safeguards
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE