• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

307.5.6 LPG Containers

NYC Fire Code 2014 > 3 General Precautions Against Fire > 307 Open Fires > 307.5 Portable Outdoor Barbecues > 307.5.6 LPG Containers
JUMP TO FULL CODE CHAPTER
Portable outdoor barbecues fueled by LPG containers shall additionally comply with the requirements of FC307.5.6.1 and 307.5.6.2.

307.5.6.1 Group R-2 Occupancies

Only portable outdoor barbecues designed for use with LPG containers with a capacity of 16.4 ounces (0.465 kg) may be stored or used on the premises of a Group R-2 occupancy. Indoor storage of 16.4-ounce (0.465 kg) LPG containers for this or any other purpose is limited to a maximum of four such containers per dwelling unit.

307.5.6.2 Group R-3 Occupancies

Portable outdoor barbecues designed for use with LPG containers with a capacity of 20 pounds (9.08 kg) or LPG containers with a capacity of 16.4 ounces (0.465 kg) may be stored or used on the premises of a Group R-3 occupancy. Twenty-pound LPG containers shall not be stored or used indoors, or on any rooftop or balcony. A maximum of two 20-pound LPG containers may be used to fuel a portable outdoor barbecue. Indoor storage of 16.4-ounce (0.465 kg) LPG containers for this or any other purpose is limited to a maximum of four such containers per dwelling unit.

Related Code Sections


623.1.1 Specific Appliances, LPG
Except as may be permitted by the New York City Fire Code , cooking appliances using LPG are prohibited ...
NYC Fuel Gas Code 2014 > 6 Specific Appliances > 623 Cooking Appliances > 623.1 Cooking Appliances > 623.1.1 LPG
623.1.1 Specific Appliances, LPG
Except as may be permitted by the New York City Fire Code, cooking appliances using LPG are prohibited ...
NYC Fuel Gas Code 2008 > 6 Specific Appliances > 623 Cooking Appliances > 623.1 Cooking Appliances > 623.1.1 LPG
623.1.1 Specific Appliances, LPG
Except as may be permitted by the New York City Fire Code , cooking appliances using LPG are prohibited ...
NYC Fuel Gas Code 2022 > 6 Specific Appliances > 623 Cooking Appliances > 623.1 Cooking Appliances > 623.1.1 LPG
307.4 Use and Occupancy Classification, High-Hazard Group H-2
Buildings and structures containing materials that present a deflagration hazard or a hazard from accelerated burning shall be classified as Group H ...
NYC Building Code 2014 > 3 Use and Occupancy Classification > 307 High-Hazard Group H > 307.4 High-Hazard Group H-2
307.4 Use and Occupancy Classification, High-Hazard Group H-2
Buildings and structures which contain materials that present a deflagration hazard or a hazard from accelerated burning shall be classified as Group ...
NYC Building Code 2008 > 3 Use and Occupancy Classification > 307 High-Hazard Group H > 307.4 High-Hazard Group H-2
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING