• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2104A.1.3.1.1.1.1 Low-Lift Grouted Construction

Los Angeles Building Code > 21A Masonry > 2104A Construction > 2104A.1 Masonry Construction > 2104A.1.3 Grouted Masonry > 2104A.1.3.1 General Conditions > 2104A.1.3.1.1 Reinforced Grouted Masonry > 2104A.1.3.1.1.1 General > 2104A.1.3.1.1.1.1 Low-Lift Grouted Construction
JUMP TO FULL CODE CHAPTER

Requirements for construction shall be as follows:

  1. All units in the two outer wythes shall be laid with full-shoved head joint and bed mortar joints. Masonry headers shall not project into the grout space.
  2. The minimum grout space for low-lift grout masonry shall be 21/2 inches (64 mm). All reinforcement and wire ties shall be embedded in the grout. The thickness of the grout between masonry units and reinforcment shall be a minimum of one bar diameter.
  3. One tier of a grouted reinforced masonry wall may be carried up 12 inches (305 mm) before grouting, but the other tier shall be laid up and grouted in lifts not to exceed one masonry unit in height. All grout shall be puddled with a mechanical vibrator or wood stick immediately after placing so as to completely fill all voids and to consolidate the grout. All vertical and horizontal steel shall be held firmly in place by a frame or suitable devices.
  4. Toothing of masonry walls is prohibited. Racking is to be held to a minimum.

Related Code Sections


2104A.1.3.1.1.1.1 Masonry, Low-Lift Grouted Construction
joints. Masonry headers shall not project into the grout space. The minimum grout space for low-lift grout masonry shall be 2 1 / 2 inches (64 mm). All ...
Los Angeles Building Code > 21A Masonry > 2104A Construction > 2104A.1 Masonry Construction > 2104A.1.3 Grouted Masonry > 2104A.1.3.1 General Conditions > 2104A.1.3.1.1 Reinforced Grouted Masonry > 2104A.1.3.1.1.1 General > 2104A.1.3.1.1.1.1 Low-Lift Grouted Construction
2104A.1 Masonry, Masonry Construction
of the two following methods: The low-lift method where the maximum height of construction laid before grouting is 4 feet (1220 mm), or the high-lift method ...
Los Angeles Building Code > 21A Masonry > 2104A Construction > 2104A.1 Masonry Construction
2104A.1.3.1 Masonry, General Conditions
Construction shall be one of the two following methods: The low-lift method where the maximum height of construction laid before grouting is 4 feet ...
Los Angeles Building Code > 21A Masonry > 2104A Construction > 2104A.1 Masonry Construction > 2104A.1.3 Grouted Masonry > 2104A.1.3.1 General Conditions
2104A.1.3.1.1 Masonry, Reinforced Grouted Masonry
with full-shoved head joint and bed mortar joints. Masonry headers shall not project into the grout space. The minimum grout space for low-lift grout ...
Los Angeles Building Code > 21A Masonry > 2104A Construction > 2104A.1 Masonry Construction > 2104A.1.3 Grouted Masonry > 2104A.1.3.1 General Conditions > 2104A.1.3.1.1 Reinforced Grouted Masonry
2104A.1.3.1.1.1 Masonry, General
with full-shoved head joint and bed mortar joints. Masonry headers shall not project into the grout space. The minimum grout space for low-lift grout ...
Los Angeles Building Code > 21A Masonry > 2104A Construction > 2104A.1 Masonry Construction > 2104A.1.3 Grouted Masonry > 2104A.1.3.1 General Conditions > 2104A.1.3.1.1 Reinforced Grouted Masonry > 2104A.1.3.1.1.1 General
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE