The following buildings, or portions thereof, separated from the remainder of the building by building thermal envelope assemblies complying with this code shall be exempt from the building thermal envelope provisions of this code:
  1. Those with a peak design rate of energy usage less than 3.4 Btu/hft2 (10.7 W/m2) or 1.0 watt/ft2 (10.7 W/m2) of floor area for space conditioning purposes.
  2. Those that do not contain conditioned space.

Related Code Sections

N1101.6 [RE] Energy Efficiency, (R101.5.2) Low-Energy Buildings
with this code shall be exempt from the building thermal envelope provisions of this code: Those with a peak design rate of energy usage less than 3.4 Btu/h ...
Chapter 11 [RE] Energy Efficiency
of energy in buildings. The requirements are directed toward the design of building envelopes with adequate thermal resistance and low air leakage ...
R503.2 [RE] Existing Buildings, Change in Space Conditioning
Any nonconditioned or low-energy space that is altered to become conditioned space shall be required to be brought into full compliance ...
101.4.6 Scope and Administration, Energy
The provisions of the International Energy Conservation Code shall apply to all matters governing the design and construction of buildings for energy ...