225.2.1 Lockers
Go To Full Code Chapter
Where lockers are provided, at least 5 percent, but no fewer than one of each type, shall comply with 811.
Advisory 225.2.1 Lockers. Different types of lockers may include full-size and half-size lockers, as well as those specifically designed for storage of various sports equipment.
Related Code Sections
225.2.1 Scoping Requirements, Lockers
Where lockers are provided, at least 5 percent, but no fewer than one of each type, shall comply with 811. Advisory 225.2.1 Lockers. Different ...
222 Scoping Requirements, Dressing, Fitting, and Locker Rooms
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster ...
803 Special Rooms, Spaces, and Elements, Dressing, Fitting, and Locker Rooms
Dressing, fitting, and locker rooms shall comply with 803. Advisory 803.1 General. Partitions and doors should be designed to ensure people ...
803.4 Special Rooms, Spaces, and Elements, Benches
A bench complying with 903 shall be provided within the room ...
803.5 Special Rooms, Spaces, and Elements, Coat Hooks and Shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in 308. Shelves shall be 40 inches (1015 mm ...