1204.3.4 Locations of DC Conductors
JUMP TO FULL CODE CHAPTER
Conduit, wiring systems, and raceways for photovoltaic circuits shall be located as close as possible to the ridge or hip or valley and from the hip or valley as directly as possible to an outside wall to reduce trip hazards and maximize ventilation opportunities. Conduit runs between sub arrays and to DC combiner boxes shall be installed in a manner that minimizes the total amount of conduit on the roof by taking the shortest path from the array to the DC combiner box. The DC combiner boxes shall be located such that conduit runs are minimized in the pathways between arrays. DC wiring shall be installed in metallic conduit or raceways when located within enclosed spaces in a building. Conduit shall run along the bottom of load bearing members.
Related Code Sections
1204.2.3 Energy Systems, Locations of DC Conductors
the array to the DC combiner box. The DC combiner boxes shall be located such that conduit runs are minimized in the pathways between arrays. DC wiring shall ...
California Fire Code 2019 > 12 Energy Systems > 1204 Solar Photovoltaic Power Systems > 1204.2 Access and Pathways > 1204.2.3 Locations of DC Conductors
605.11.1.2.7 Building Services and Systems, Locations of DC Conductors
the array to the DC combiner box. The DC combiner boxes shall be located such that conduit runs are minimized in the pathways between arrays. DC wiring shall ...
California Fire Code 2016 > 6 Building Services and Systems > 605 Electrical Equipment, Wiring and Hazards > 605.11 Solar Photovoltaic Power Systems > 605.11.1 Access and Pathways > 605.11.1.2 Solar Photovoltaic Systems for Group R-3 Buildings > 605.11.1.2.7 Locations of DC Conductors
R324.7.3 Building Planning, Locations of DC Conductors
the array to the DC combiner box. The
DC combiner boxes shall be located such that conduit
runs are minimized in the pathways between arrays. DC
wiring shall ...
California Residential Code 2016 > 3 Building Planning > R324 Solar Energy Systems > R324.7 Ground-Mounted Photovoltaic Systems > R324.7.3 Locations of DC Conductors
1101.4.2 Storm Drainage, Conductors
Conductors installed aboveground
in buildings shall be in accordance with the
applicable standards referenced in Table 701.2 for
aboveground drain ...
California Plumbing Code 2016 > 11 Storm Drainage > 1101.0 General > 1101.4 Material Uses > 1101.4.2 Conductors
1101.4.2 Storm Drainage, Conductors
Conductors installed aboveground
in buildings shall comply with the applicable
standards referenced in Table 701.2 for aboveground
drain, waste ...
California Plumbing Code 2019 > 11 Storm Drainage > 1101.0 General > 1101.4 Material Uses > 1101.4.2 Conductors