• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

128-13 Location of Uses in Mixed Buildings

NYC Zoning Resolution > XII Special Purpose Districts > 8 - Special ST. George District (SG) > 128-10 Use Regulations > 128-13 Location of Uses in Mixed Buildings
JUMP TO FULL CODE CHAPTER

The provisions of Section 32-422 (Location of floors occupied by commercial uses) are modified to permit dwelling units on the same story as a commercial use provided no access exists between such uses at any level containing dwelling units and provided any commercial uses are not located directly over any dwelling units. However, such commercial use may be located over dwelling units by authorization of the City Planning Commission upon a finding that sufficient separation of residential uses from commercial uses exists within the building.

Related Code Sections


509.1 General Building Heights and Areas; Separation of Occupancies, General
Incidental uses listed in Table 509 and located within single occupancy or mixed occupancy buildings shall comply with the provisions of this section ...
NYC Building Code 2014 > 5 General Building Heights and Areas; Separation of Occupancies > 509 Incidental Uses > 509.1 General
415.7.2.1 Special Detailed Requirements Based on Use and Occupancy, Mixed Occupancies
Where the storage tank area is located in a building of two or more occupancies, and the quantity of liquid exceeds the maximum allowable quantity ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.7 Group H-2 > 415.7.2 Flammable and Combustible Liquids > 415.7.2.1 Mixed Occupancies
415.6.2.1 Special Detailed Requirements Based on Use and Occupancy, Mixed Occupancies
Where the storage tank area is located in a building of two or more occupancies, and the quantity of liquid exceeds the maximum allowable quantity ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 415 Groups H-1, H-2, H-3, H-4 and H-5 > 415.6 Group H-2 > 415.6.2 Flammable and Combustible Liquids > 415.6.2.1 Mixed Occupancies
508.3 General Building Heights and Areas; Separation of Occupancies, Mixed Occupancies
in a separate and detached building or structure. Incidental use areas in accordance with Section 508.2 ...
NYC Building Code 2008 > 5 General Building Heights and Areas; Separation of Occupancies > 508 Incidental Use Areas and Mixed Occupancies > 508.3 Mixed Occupancies
§27-295 Building Limitations, Mixed Districts
Any building located on the boundary line of a fire district, so that it is both inside and outside the district, shall be of a type of construction ...
NYC 1968 Code (Vol I) > 4 Building Limitations > 3 Fire Districts > §27-295 Mixed Districts
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE