P-1202.4 Location of Trapped Fixtures or Receptacles Receiving Indirect Wastes
Go To Full Code Chapter
Fixture or receptacles receiving
indirect wastes shall not be located within living quarters, and no indirect waste shall discharge into a lavatory, water
closet, urinal, bathtub, shower, drinking fountain, or other similar fixture in use for its customary purpose.
P-1202.4.1 Air Conditioning Condensate
A drain for receiving condensate from air conditioning systems shall be
permitted to discharge into a laundry tray fixture or service sink fixture in accordance with Section P-1202.2. In
one-family and two-family residences, the condensate water shall be permitted to discharge onto a seeded area that
is part of the property where the air conditioning system is located.
Upcodes Diagrams
Related Code Sections
P-1202.4 Indirect and Special Waste, Location of Trapped Fixtures or Receptacles Receiving Indirect Wastes
Fixture or receptacles receiving
indirect wastes shall not be located within living quarters, and no indirect waste shall discharge into a lavatory ...
Section P-1204 Indirect and Special Waste, Venting of Indirect Waste
Indirect waste stacks receiving fixtures on more than one floor or waste pipes longer
than 100 feet, or those draining more than ...
Section 802 Indirect/Special Waste, Indirect Wastes
sinks shall discharge through an indirect waste pipe as specified in Sections 802.1.1 through 802.1.7. Fixtures not required to be indirectly ...
P-1204.2 Indirect and Special Waste, Vent Through Roof
Indirect waste stacks receiving fixtures on more than one floor or waste pipes longer
than 100 feet, or those draining more than one trapped fixture ...
802.4 Indirect/Special Waste, Waste Receptors
connecting directly to a drainage system, a laundry tray waste line without a fixture trap shall connect to a standpipe for an automatic clothes ...