2404.2 Location of Spray-Finishing Operations
JUMP TO FULL CODE CHAPTER
Spray-finishing operations conducted in buildings used for Group A, E, I or R occupancies shall be located in a spray room protected with an approved automatic sprinkler system installed in accordance with Section 903.3.1.1 and separated vertically and horizontally from the remainder of the building by fire barrier walls and horizontal assemblies with not less than a 1-hour fire-resistance rating in accordance with the Building Code of New York State. In other occupancies, spray-finishing operations shall be conducted in a spray room, spray booth or limited spraying space approved for such use.
Exceptions:
- Automobile undercoating spray operations and spray-on automotive lining operations conducted in areas with approved natural or mechanical ventilation shall be exempt from the provisions of Section 2404 when approved and where utilizing Class IIIA or IIIB combustible liquids.
- In buildings other than Group A, E, I or R occupancies, approved limited spraying space in accordance with Section 2404.9.
- Resin application areas used for manufacturing of reinforced plastics complying with Section 2409 shall not be required to be located in a spray room, spray booth or spraying space.
Related Code Sections
1504.2 Flammable Finishes, Location of Spray-Finishing Operations
Spray finishing operations conducted in buildings used for Group A, E, I or R occupancies shall be located in a spray room protected with an approved ...
2010 Fire Code of NY > 15 Flammable Finishes > 1504 Spray Finishing > 1504.2 Location of Spray-Finishing Operations
2404.2 Flammable Finishes, Location of Spray-Finishing Operations
Spray-finishing operations conducted in buildings used for Group A, E, I or R occupancies shall be located in a spray room protected ...
Fire Code 2015 of New York State > 24 Flammable Finishes > 2404 Spray Finishing > 2404.2 Location of Spray-Finishing Operations
2404.2 Flammable Finishes, Location of Spray-Finishing Operations
Spray-finishing operations conducted in buildings used for Group A, E, I or R occupancies shall be located in a spray room protected ...
2020 Fire Code of NYS > 24 Flammable Finishes > 2404 Spray Finishing > 2404.2 Location of Spray-Finishing Operations
Section 2403 Flammable Finishes, Protection of Operations
parts located in resin application areas, including but not limited to exhaust ducts, ventilation fans, spray application equipment, workpieces ...
Section 2403 Flammable Finishes, Protection of Operations
Cleaning machines for spray guns and equipment shall not be located in areas open to the public and shall ...