• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R608.5.4.2 Location of Reinforcement in Walls

Los Angeles Residential Code > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.5 Materials > R608.5.4 Reinforcement Installation Details > R608.5.4.2 Location of Reinforcement in Walls
JUMP TO FULL CODE CHAPTER
For location of reinforcement in foundation walls and above-grade walls, see Sections R404.1.3.3.7.2 and R608.6.5, respectively.

Related Code Sections


R403.1.3.5.2 Foundations, Location of Reinforcement in Wall
The center of vertical reinforcement in stem walls shall be located at the centerline of the wall. Horizontal and vertical reinforcement shall ...
Los Angeles Residential Code > 4 Foundations > R403 Footings > R403.1 General > R403.1.3 Footing and Stem Wall Reinforcing in Seismic Design Categories D0, D1, and D2 > R403.1.3.5 Reinforcement > R403.1.3.5.2 Location of Reinforcement in Wall
R403.1.3.5.2 Foundations, Location of Reinforcement in Wall
The center of vertical reinforcement in stem walls shall be located at the centerline of the wall. Horizontal and vertical reinforcement shall ...
Los Angeles Residential Code > 4 Foundations > R403 Footings > R403.1 General > R403.1.3 Footing and stem wall reinforcing in Seismic Design Categories D0, D1, and D2 > R403.1.3.5 Reinforcement > R403.1.3.5.2 Location of Reinforcement in Wall
R404.1.3.3.7.2 Foundations, Location of Reinforcement in Wall
The center of vertical reinforcement in basement walls determined from Tables R404.1.2(2) through R404.1.2(7) shall be located at the centerline ...
Los Angeles Residential Code > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.3 Concrete Foundation Walls > R404.1.3.3 Concrete, Materials for Concrete, and Forms > R404.1.3.3.7 Reinforcement > R404.1.3.3.7.2 Location of Reinforcement in Wall
R404.1.3.3.7.2 Foundations, Location of Reinforcement in Wall
The center of vertical reinforcement in basement walls determined from Tables R404.1.2(2) through R404.1.2(7) shall be located at the centerline ...
Los Angeles Residential Code > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.3 Concrete Foundation Walls > R404.1.3.3 Concrete, Materials for Concrete, and Forms > R404.1.3.3.7 Reinforcement > R404.1.3.3.7.2 Location of Reinforcement in Wall
R608.5.4.2 Wall Construction, Location of Reinforcement in Walls
For location of reinforcement in foundation walls and above-grade walls, see Sections R404.1.3.3.7.2 and R608.6.5, respectively ...
Los Angeles Residential Code > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.5 Materials > R608.5.4 Reinforcement Installation Details > R608.5.4.2 Location of Reinforcement in Walls
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE