• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

403.4 Location of Employee Toilet Facilities in Occupancies Other Than Assembly or Mercantile

NYC Plumbing Code 2008 > 4 Fixtures, Faucets and Fixture Fittings > 403 Minimum Plumbing Facilities > 403.4 Location of Employee Toilet Facilities in Occupancies Other Than Assembly or Mercantile
JUMP TO FULL CODE CHAPTER
Access to toilet facilities in occupancies other than mercantile and assembly occupancies shall be from within the employees' working area. Employee facilities shall be either separate facilities or combined employee and public facilities.
  Exception: Facilities that are required for employees in storage structures or kiosks, and are located in adjacent structures under the same ownership, lease or control, shall be a maximum travel distance of 500 feet (152 m) from the employees' working area.

403.4.1 Travel Distance

The required toilet facilities in occupancies other than assembly or mercantile shall be located not more than one story above or below the employee's working area and the path of travel to such facilities shall not exceed a distance of 500 feet (152 m).
  Exception: The location and maximum travel distances to required employee toilet facilities in factory and industrial occupancies are permitted to exceed that required in Section 403.4.1, provided the location and maximum travel distance are approved by the commissioner.

Related Code Sections


403.4 Fixtures, Faucets and Fixture Fittings, Location of Employee Toilet Facilities in Occupancies Other Than Assembly or Mercantile
Access to toilet facilities in occupancies other than mercantile and assembly occupancies shall be from within the employees' working area. Employee ...
NYC Plumbing Code 2008 > 4 Fixtures, Faucets and Fixture Fittings > 403 Minimum Plumbing Facilities > 403.4 Location of Employee Toilet Facilities in Occupancies Other Than Assembly or Mercantile
1109.2.1 Accessibility, Unisex Toilet and Bathing Rooms
In assembly and mercantile occupancies, an accessible unisex toilet room shall be provided where an aggregate of six or more male and female water ...
NYC Building Code 2008 > 11 Accessibility > 1109 Other Features and Facilities > 1109.2 Toilet and Bathing Facilities > 1109.2.1 Unisex Toilet and Bathing Rooms
1109.2 Accessibility, Toilet and Bathing Rooms
occupancy, only those water closets required for the assembly or mercantile occupancy shall be used to determine the family or assisted-use toilet room ...
NYC Building Code 2014 > 11 Accessibility > 1109 Other Features and Facilities > 1109.2 Toilet and Bathing Rooms
Section 403 Fixtures, Faucets and Fixture Fittings, Minimum Plumbing Facilities
Employees shall be provided with toilet facilities in all occupancies. The number of plumbing fixtures located within the required employee ...
NYC Plumbing Code 2014 > 4 Fixtures, Faucets and Fixture Fittings > 403 Minimum Plumbing Facilities
1109.2.1 Accessibility, Family or Assisted-Use Toilet and Bathing Rooms
In assembly and mercantile occupancies, an accessible family or assisted-use toilet room shall be provided where an aggregate of six or more male ...
NYC Building Code 2014 > 11 Accessibility > 1109 Other Features and Facilities > 1109.2 Toilet and Bathing Rooms > 1109.2.1 Family or Assisted-Use Toilet and Bathing Rooms
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE