403.5 Location of Employee Toilet Facilities in Mercantile and Assembly Occupancies
Go To Full Code Chapter
Employees shall be provided with toilet facilities in building and tenant spaces utilized as restaurants, nightclubs, places of public assembly and mercantile occupancies. The employee facilities shall be either separate facilities or combined employee and public facilities. The required toilet facilities shall be located not more than one story above or below the employees' work area and the path of travel to such facilities, in other than covered malls, shall not exceed a distance of 500 feet (152,440 mm). The path of travel to required facilities in covered malls shall not exceed a distance of 300 feet (91,440 mm).
Exception: Employee toilet facilities shall not be required in tenant spaces where the travel distance from the main entrance of the tenant space to a central toilet area does not exceed 300 feet (91,440 mm) and such central toilet facilities are located not more than one story above or below the tenant space.
Upcodes Diagrams
Related Code Sections
403.5 Fixtures, Faucets and Fixture Fittings, Location of Employee Toilet Facilities in Mercantile and Assembly Occupancies
and mercantile occupancies. The employee facilities shall be either separate facilities or combined employee and public facilities. The required toilet ...
403.1.2 Fixtures, Faucets and Fixture Fittings, Family or Assisted-Use Toilet and Bath Fixtures
to be included in the number of required fixtures for either the male or female occupants in assembly and mercantile occupancies ...
403.1.2 Fixtures, Faucets and Fixture Fittings, Family or Assisted-Use Toilet and Bath Fixtures
to be included in the number of required fixtures for either the male or female occupants in assembly and mercantile occupancies ...
1109.2.1 Accessibility, Unisex Toilet and Bathing Rooms
In assembly and mercantile occupancies, an accessible unisex toilet room shall be provided where an aggregate of six or more male and female water ...
Section 403 Fixtures, Faucets and Fixture Fittings, Minimum Plumbing Facilities
Building Code.
b. Toilet facilities for employees shall be separate from facilities for inmates or patients.
c. A single-occupant toilet ...