// CODE SNIPPET
13-241 Location of Curb Cuts
JUMP TO FULL CODE CHAPTER
For accessory off-street parking facilities, automobile rental establishments and public parking lots, curb cuts are required for entry and exit to such parking facilities. Such curb cuts:
(a) shall not be permitted within 50 feet of the intersection of any two street lines, except where the Commissioner of Buildings certifies that such location:
(1) is not hazardous to traffic safety;
(2) is not likely to create traffic congestion; and
(3) will not unduly inhibit surface traffic or pedestrian flow.
The Commissioner of Buildings may refer such matter to the Department of Transportation, or its successor, for a report;
(b) shall not be located within two and one-half feet of any side lot line of the zoning lot, or prolongation thereof;
(c) for accessory off-street parking facilities and automobile rental establishments, shall not be located on a wide street, except where authorized pursuant to Section 13-441 (Curb cuts); and
(d) for public parking lots, shall not be permitted on the following wide streets, except where authorized pursuant to Section 13-441:
(1) 14th Street, from Fourth Avenue to Seventh Avenue;
(2) Avenue of the Americas, from 23rd Street to 32nd Street;
(3) Canal Street, from the Bowery to West Broadway;
(4) Church Street, from Park Place to Worth Street;
(5) Delancey Street, from Clinton Street to the west side of Orchard Street;
(6) Fifth Avenue;
(7) Seventh Avenue, from 23rd Street to 32nd Street; and
(8) Worth Street, from Centre Street to Church Street.
Related Code Sections
406.9.2 Special Detailed Requirements Based on Use and Occupancy, Permit Required
, retaining walls, and open spaces on adjoining premises;
Retaining walls to be built;
Location and dimensions of curb cuts, driveways ...
NYC Building Code 2022 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor-Vehicle-Related Occupancies > 406.9 Open Parking Lots > 406.9.2 Permit Required
406.7.3 Special Detailed Requirements Based on Use and Occupancy, Permit Required
walls, and open spaces on adjoining premises; and Retaining walls to be built; and Location and dimensions of curb cuts, driveways, and enclosures ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor-Vehicle-Related Occupancies > 406.7 Open Parking Lots > 406.7.3 Permit Required
406.7.3 Special Detailed Requirements Based on Use and Occupancy, Permit Required
to be built; and 6. Location and dimensions of curb cuts, driveways, and enclosures; and 7. Drainage diagram; and 8 ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor Vehicle-Related Occupancies > 406.7 Open Parking Lots > 406.7.3 Permit Required
106.3 Administration, Lot Diagram
construction including parking and curb cuts; all existing structures on the zoning lot and their distances from lot and street lines; the established grade ...
107.3 Administration, Lot Diagram
construction including parking and curb cuts; all existing structures on the zoning lot and their distances from lot and street lines; the established grade ...