• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3404.2.7.5.6 Location of Connections

NYC Fire Code 2014 > 34 Flammable and Combustible Liquids > 3404 Storage > 3404.2 Tank Storage > 3404.2.7 Design and Installation Requirements for Tanks > 3404.2.7.5 Tank Openings Other Than Vents > 3404.2.7.5.6 Location of Connections
JUMP TO FULL CODE CHAPTER
Filling, withdrawal and vapor-recovery connections that are made and broken shall be located outdoors at a location away from sources of ignition and not less than 10 feet (3048 mm) away from building openings. Such connections shall be closed and liquid-tight when not in use and shall be properly identified.

Related Code Sections


905.3.3.2 Fire Protection Systems, Location of Hose Connections
Hose connections shall be provided in accordance with Section 905.4 and at each of the following locations:   1. Within the mall ...
NYC Building Code 2008 > 9 Fire Protection Systems > 905 Standpipe Systems > 905.3 Required Installations > 905.3.3 Covered Mall Buildings > 905.3.3.2 Location of Hose Connections
905.3.3.2 Fire Protection Systems, Location of Hose Connections
Hose connections shall be provided in accordance with Section 905.4 and at each of the following locations: Within the mall at the entrance to each ...
NYC Building Code 2014 > 9 Fire Protection Systems > 905 Standpipe Systems > 905.3 Required Installations > 905.3.3 Covered Mall Buildings > 905.3.3.2 Location of Hose Connections
912.2.1.1 Fire Protection Systems,
One Fire Department connection shall be provided for each 300 feet (91 140 mm) of exterior building wall or fraction thereof facing upon each street ...
NYC Building Code 2014 > 9 Fire Protection Systems > 912 Fire Department Connections > 912.2 Location > 912.2.1 Fire Department Connections > 912.2.1.1
501.4 Water Heaters, Location
Water heaters and storage tanks shall be located and connected so as to provide access for observation, maintenance, servicing and replacement ...
NYC Plumbing Code 2008 > 5 Water Heaters > 501 General > 501.4 Location
501.4 Water Heaters, Location
Water heaters and storage tanks shall be located and connected so as to provide access for observation, maintenance, servicing and replacement ...
NYC Plumbing Code 2014 > 5 Water Heaters > 501 General > 501.4 Location
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE