517.2 Location of Appliances
JUMP TO FULL CODE CHAPTER
Appliances shall be located
with respect to building construction and other equipment so
as to permit access to the appliance. [NFPA 96:14.2.1]
Solid-fuel cooking appliances
shall not be installed in confined spaces. [NFPA 96:14.2.2]
Exception: Solid-fuel cooking appliances listed for installation in confined spaces such as alcoves shall be installed in accordance with the terms of the listing and the manufacturer's installation instructions. [NFPA 96:14.2.3]
Exception: Solid-fuel cooking appliances listed for installation in confined spaces such as alcoves shall be installed in accordance with the terms of the listing and the manufacturer's installation instructions. [NFPA 96:14.2.3]
Solid-fuel cooking appliances
shall not be installed in a location where gasoline or
other flammable vapors or gases are present. [NFPA
96:14.2.4]