// CODE SNIPPET
25-631 Location and Width of Curb Cuts in Certain Districts
NYC Zoning Resolution > II - Residence District Regulations > 5 Accessory Off-Street Parking and Loading Regulations > 25-60 Additional Regulations for Permitted or Required Accessory Off-Street Parking Spaces > 25-63 Location of Access to the Street > 25-631 Location and Width of Curb Cuts in Certain Districts
Go To Full Code Chapter
All curb cuts on zoning lots with buildings containing residences shall comply with the provisions of this Section, except that, in lower density growth management areas, the provisions of Section 25-632 shall apply. The minimum width of a curb cut shall be eight feet, including splays. In addition, for non-conforming buildings in all districts, the provisions of Section 25-633 (Curb cut restrictions for certain buildings in R1 through R5 Districts) shall apply.
R2A
- In the district indicated, the maximum width of a curb cut shall be 18 feet, and the maximum width of a driveway within a front yard shall be 20 feet. All zoning lots shall maintain at least 18 feet of uninterrupted curb space along each street frontage.R2X R3 R4 R5
- In the districts indicated, except R4B and R5B Districts, curb cuts shall comply with the following provisions:
- For zoning lots containing residences where not more than two accessory parking spaces are required:
- for zoning lots with less than 50 feet of frontage along a street, only one curb cut, having a maximum width, including splays, of 10 feet, shall be permitted;
- for zoning lots with at least 50 feet of frontage along a street, no more than two curb cuts shall be permitted along such street frontage. If one curb cut is provided, such curb cut shall have a maximum width, including splays, of 18 feet. If two curb cuts are provided, the maximum width of each curb cut, including splays, shall be 10 feet, and a minimum distance of 30 feet of uninterrupted curb space shall be provided between such curb cuts;
- wherever accessory parking spaces are provided in adjacent side lot ribbons on zoning lots subdivided after June 30, 1989, the curb cuts giving access to such side lot ribbons shall be contiguous (paired), so that only one curb cut, having a maximum width of 18 feet, including splays, shall serve both side lot ribbons; and
- a minimum distance of 16 feet of uninterrupted curb space shall be maintained between all curb cuts constructed after June 30, 1989, provided that this requirement shall not apply to zoning lots existing both on June 30, 1989, and April 14, 2010, that are less than 40 feet wide and where at least 16 feet of uninterrupted curb space is maintained along the street in front of the zoning lot; or
- For zoning lots containing residences where more than two accessory parking spaces are required:
- zoning lots with 35 feet or more of frontage along a street shall maintain a minimum distance of 16 feet of uninterrupted curb space along such street;
- a minimum distance of 16 feet of uninterrupted curb space shall be maintained between all curb cuts constructed after June 30, 1989, provided that this requirement shall not apply to any zoning lot existing both on June 30, 1989 and April 14, 2010, that is less than 40 feet wide and where at least 16 feet of uninterrupted curb space is maintained in front of such zoning lot along the street;
- all driveways shall be located at least 13 feet from any other driveway on the same or adjoining zoning lots. However, driveways may be paired with other driveways on the same or adjoining zoning lots, provided the aggregate width of such paired driveways, including any space between them, does not exceed 20 feet. Curb cuts accessing such paired driveway shall have a minimum width of 15 feet and a maximum width, including splays, of 18 feet; and
- except for paired driveways as set forth in paragraph (b)(2)(iii) of this Section, the maximum width of a curb cut accessing less than 50 parking spaces shall be 12 feet, including splays, and the maximum width of a curb cut accessing more than 50 parking spaces shall be 22 feet, including splays. However, where Fire Department regulations set forth in the Administrative Code of the City of New York require curb cuts of greater width, such curb cuts may be increased to the minimum width acceptable to the Fire Department.R4B R5B
- In the districts indicated, curb cuts are permitted only on zoning lots with at least 40 feet of street frontage and existing on the effective date of establishing such districts on the zoning maps. Any such zoning lot may be subdivided; however, curb cuts are permitted only for a resulting subdivided zoning lot that has at least 40 feet of street frontage. For detached, semi-detached and zero lot line buildings, the width and location of curb cuts shall be in accordance with paragraph (b)(1), inclusive, of this Section. For attached buildings and building segments, and for multiple dwellings in R5B Districts, at least 34 feet of uninterrupted curb space shall be maintained between all curb cuts constructed after June 30, 1989, provided that this requirement shall not apply to zoning lots existing on both June 30, 1989, and April 14, 2010, that are less than 76 feet wide and where at least 34 feet of uninterrupted curb space is maintained along the street in front of the zoning lot.
For zoning lots with less than 40 feet of street frontage and existing on the effective date of establishing such districts on the zoning maps, curb cuts shall be prohibited.R6 R7 R8 - In the districts indicated without a letter suffix, for zoning lots containing non-Quality Housing buildings or non-Quality Housing building segments, each of which contains not more than three dwelling units, accessory off-street parking spaces shall be located in accordance with the provisions of paragraph (b)(2), inclusive, of this Section.R6 R7 R8
- In the districts indicated, except as provided for in paragraph (d) of this Section, only one curb cut, having a maximum width of 12 feet, including splays, shall be permitted on any street frontage of a zoning lot. However, where a curb cut accesses a group parking facility with 50 or more spaces, the maximum width of a curb cut shall be 22 feet, including splays, or alternatively, two curb cuts shall be permitted to access such group parking facility, each with a maximum width of 12 feet, including splays, and spaced at least 60 feet apart. For zoning lots subdivided after April 14, 2010, curb cuts shall only be permitted along the street frontage of such subdivided zoning lot where at least 34 feet of uninterrupted curb space is maintained, and shall comply with the width and spacing requirements of this paragraph, (e).These curb cut provisions shall apply as follows:
- In R6, R7 and R8 Districts without a letter suffix, to non-Quality Housing buildings or non-Quality Housing building segments, any of which contain four or more dwelling units;
- In R6, R7 and R8 Districts without a letter suffix, to Quality Housing buildings or Quality Housing building segments;
- In R6A, R7A, R7D, R7X, R8A and R8X Districts, to all buildings; and
- In R6B, R7B and R8B Districts, to zoning lots occupied by a building with a street wall at least 40 feet in width or, for zoning lots with multiple building segments, only where such curb cut is in front of a building segment with a street wall at least 40 feet in width. On such zoning lots, curb cuts shall be permitted only on the street frontage that is at least 40 feet wide. On all other zoning lots in R6B, R7B and R8B Districts, curb cuts shall be prohibited.
- Modification of curb cut location requirements:
R2X R3 R4 R5 R6 R7 R8
- In the districts indicated, the location and width of curb cuts, as required by the provisions of this Section, may be modified if the Commissioner of Buildings certifies that the specified curb cut locations would require the removal of shade trees maintained by the City of New York. The Commissioner of Buildings may refer such matter to the Department of Parks and Recreation and the Department of Transportation for reports, and may base the determination on such reports.
R6 R7 R8 - In the districts indicated, except R6, R7 or R8 Districts with a letter suffix, the City Planning Commission may authorize modification of the location and width of curb cuts as required by the provisions of this Section provided that the Commission finds that:
- the proposed modification does not adversely affect the character of the surrounding area; and
- where more than one curb cut is provided, the curb cuts are arranged to foster retention of curbside parking spaces along the street frontage of the zoning lot.
Related Code Sections
406.10 Special Detailed Requirements Based on Use and Occupancy, Curb Cuts and Driveways
(2438 mm) in width and shall not exceed the length of the curb cut, not including the lengths
of the splays. For all other motor vehicles ...
406 Accessible Routes, Curb Ramps
Curb ramps and the flared sides of curb ramps shall be located so they do not project into vehicular traffic lanes, parking spaces, or parking access ...
3202.2.2.4 Encroachments Into the Public Right-of-Way, Curb Cuts
Vehicular access curb cuts that can no longer serve as vehicular access across a curb or sidewalk shall be removed and the curb ...
3202.2.2.4 Encroachments Into the Public Right-of-Way, Curb Cuts
Vehicular access curb cuts that can no longer serve as vehicular access across a curb or sidewalk, including where an existing ...
406.7.6 Special Detailed Requirements Based on Use and Occupancy, Curb Cuts
For the purpose of this section, a curb cut shall include all splays when determining the total length of cut curb. Unless otherwise required ...