• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(b) 320.6.2 Location and Installation

2017 Ohio Fire Code > Ohio Administrative Code 1301:7-7-03 General Requirements > 320 Mobile Food Units > 320.6 LP-gas > 320.6.2 Location and Installation
JUMP TO FULL CODE CHAPTER
Supply systems for mobile food units shall comply with the following:
  1. LP-Gas supply systems used for a mobile food unit, including the containers, shall be installed either on the outside of the vehicle or in a recess or cabinet that is vapor tight to the inside of the vehicle but accessible from and vented to the outside, with the vents located near the top and bottom of the enclosure and 1 m (3 ft) horizontally away from any opening into the vehicle.
  2. Except as otherwise provided in paragraph (T)(6)(b)(iii)(320.6.2) of this rule, LP-Gas containers shall be mounted securely on the vehicle or within the enclosing recess or cabinet and secured with non-combustible material or devices, shall be kept in a secure manner at all times, and shall comply with the following:
    1. Cylinders shall be located to minimize exposure to excessive temperature rises, physical damage, or tampering.
    2. When secured to the rear of the vehicle, propane tanks shall be mounted with a minimum 30" clearance from the bottom of the tank to the ground.
    3. LP-Gas containers shall not be installed on the roof of the vehicle.
    4. Where LP-Gas containers are mounted within the vehicle housing, the housing shall be secure to the vehicle and any removable portions of the housing shall be secured to the housing while in transit.
    5. All LP-Gas container valves, appurtenances, and connections shall be protected to prevent damage from accidental contact with stationary objects, loose objects, stones, mud, or ice thrown, up from the ground or floor, and damage due to overturn or similar vehicular accident.
    6. LP-Gas cylinders shall have permanent protection for cylinder valves and connections.
    7. Where LP-Gas cylinders are located on the outside of a vehicle, weather protection shall be provided.
    8. All materials or devices used to secure LP-Gas containers shall be made of non-combustible material.
  3. LP Gas containers may be removed from the mobile food unit during operation activities. When so removed, propane tanks shall be secured to a stationary object or otherwise securely stabilized to prevent movement, overturn and damage at all times while operation activities are occurring.

Related Code Sections


320.6.2 Ohio Administrative Code 1301:7-7-03 General Requirements, Location and Installation
, shall be installed either on the outside of the vehicle or in a recess or cabinet that is vapor tight to the inside of the vehicle but accessible ...
2017 Ohio Fire Code > Ohio Administrative Code 1301:7-7-03 General Requirements > 320 Mobile Food Units > 320.6 LP-gas > 320.6.2 Location and Installation
17.7.5.5 Initiating Devices, Location and Installation of Detectors in Air Duct Systems
Air duct detectors shall be installed in such a way as to obtain a representative sample of the airstream. This installation ...
National Fire Alarm and Signaling Code 2016 of Ohio > 17 Initiating Devices > 17.7 Smoke-Sensing Fire Detectors > 17.7.5* Smoke Detectors for Control of Smoke Spread > 17.7.5.5 Location and Installation of Detectors in Air Duct Systems
17.7.5.5.3 Initiating Devices,
Detectors shall be mounted in accordance with the manufacturer's published instructions and shall be accessible for cleaning by providing access doors ...
National Fire Alarm and Signaling Code 2016 of Ohio > 17 Initiating Devices > 17.7 Smoke-Sensing Fire Detectors > 17.7.5* Smoke Detectors for Control of Smoke Spread > 17.7.5.5 Location and Installation of Detectors in Air Duct Systems > 17.7.5.5.3
17.7.5.5.6 Initiating Devices,
Detectors shall be listed for operation over the complete range of air velocities, temperature, and humidity expected at the detector when the air ...
National Fire Alarm and Signaling Code 2016 of Ohio > 17 Initiating Devices > 17.7 Smoke-Sensing Fire Detectors > 17.7.5* Smoke Detectors for Control of Smoke Spread > 17.7.5.5 Location and Installation of Detectors in Air Duct Systems > 17.7.5.5.6
(1) Special Occupancies, Fixed Electrical Equipment
Electrical equipment in a fixed position shall be located above the level of any defined Class I location or shall be identified for the location ...
National Electrical Code 2017 of Ohio > 5 Special Occupancies > 511 Commercial Garages, Repair and Storage > 511.7 Wiring and Equipment Installed Above Class I Locations > (B) Electrical Equipment Installed Above Class I Locations > (1) Fixed Electrical Equipment
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING