• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.307(g)(2) Location and General Requirements

OSHA 1910 General Industry > S Electrical > 1910.307 Hazardous (Classified) Locations > 1910.307(g) Class I, Zone 0, 1, and 2 Locations > 1910.307(g)(2) Location and General Requirements
JUMP TO FULL CODE CHAPTER

1910.307(g)(2)(i)

Locations shall be classified depending on the properties of the flammable vapors, liquids, or gases that may be present and the likelihood that a flammable or combustible concentration or quantity is present. Where pyrophoric materials are the only materials used or handled, these locations need not be classified.

1910.307(g)(2)(iii)

All threaded conduit shall be threaded with an NPT (National (American) Standard Pipe Taper) standard conduit cutting die that provides 3/4-in. taper per foot. The conduit shall be made wrench tight to prevent sparking when fault current flows through the conduit system and to ensure the explosionproof or flameproof integrity of the conduit system where applicable.

1910.307(g)(2)(iv)

Equipment provided with threaded entries for field wiring connection shall be installed in accordance with paragraph (g)(2)(iv)(A) or (g)(2)(iv)(B) of this section.

1910.307(g)(2)(iv)(A)

For equipment provided with threaded entries for NPT threaded conduit or fittings, listed conduit, conduit fittings, or cable fittings shall be used.

1910.307(g)(2)(iv)(B)

For equipment with metric threaded entries, such entries shall be identified as being metric, or listed adaptors to permit connection to conduit of NPT-threaded fittings shall be provided with the equipment. Adapters shall be used for connection to conduit or NPT-threaded fittings.

1910.307(g)(2)(ii)

Each room, section, or area shall be considered individually in determining its classification.

Related Code Sections


1910.307(g)(2) Electrical, Location and General Requirements
Locations shall be classified depending on the properties of the flammable vapors, liquids, or gases that may be present and the likelihood ...
OSHA 1910 General Industry > S Electrical > 1910.307 Hazardous (Classified) Locations > 1910.307(g) Class I, Zone 0, 1, and 2 Locations > 1910.307(g)(2) Location and General Requirements
1910.307(g)(2)(iv)(B) Electrical,
For equipment with metric threaded entries, such entries shall be identified as being metric, or listed adaptors to permit connection to conduit ...
OSHA 1910 General Industry > S Electrical > 1910.307 Hazardous (Classified) Locations > 1910.307(g) Class I, Zone 0, 1, and 2 Locations > 1910.307(g)(2) Location and General Requirements > 1910.307(g)(2)(iv) > 1910.307(g)(2)(iv)(B)
1910.103(c)(2)(i)(c) Hazardous Materials,
When locating liquefied hydrogen storage containers near above-ground flammable liquid storage or liquid oxygen storage, it is advisable to locate ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.103 Hydrogen > 1910.103(c) Liquefied Hydrogen Systems > 1910.103(c)(2) Location of Liquefied Hydrogen Storage > 1910.103(c)(2)(i) General Requirements > 1910.103(c)(2)(i)(c)
1910.103(c)(2)(i)(f) Hazardous Materials,
feet above grade to a safe location as required in paragraph (c)(1)(iv)(b) of this section. TABLE H-3 - MAXIMUM TOTAL QUANTITY OF ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.103 Hydrogen > 1910.103(c) Liquefied Hydrogen Systems > 1910.103(c)(2) Location of Liquefied Hydrogen Storage > 1910.103(c)(2)(i) General Requirements > 1910.103(c)(2)(i)(f)
1910.103(c)(2)(i)(a) Hazardous Materials,
The storage containers shall be located so that they are readily accessible to mobile supply equipment at ground level and to authorized personnel ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.103 Hydrogen > 1910.103(c) Liquefied Hydrogen Systems > 1910.103(c)(2) Location of Liquefied Hydrogen Storage > 1910.103(c)(2)(i) General Requirements > 1910.103(c)(2)(i)(a)
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE