• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

604.2 Location

2010 ADA Standards > 6 Plumbing Elements and Facilities > 604 Water Closets and Toilet Compartments > 604.2 Location
JUMP TO FULL CODE CHAPTER
The water closet shall be positioned with a wall or partition to the rear and to one side.  The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in 604.8.2.  Water closets shall be arranged for a left-hand or right-hand approach.
Figure 604.2 Water Closet Location
Figure (a) shows a wheelchair accessible water closet, with space on one side, and figure (b) shows an ambulatory accessible water closet, with stall walls and grab bars on both sides.  The water closet centerline is shown to be 16 to 18 inches (405 to 455 mm) from the side wall.

Related Code Sections


206.3 Scoping Requirements, Location
accessible routes shall coincide with or be located in the same area as general circulation paths.  Where circulation paths are interior ...
2010 ADA Standards > 2 Scoping Requirements > 206 Accessible Routes > 206.3 Location
208.3 Scoping Requirements, Location
spaces complying with 502 that serve a particular building or facility shall be located on the shortest accessible route from parking to an entrance ...
2010 ADA Standards > 2 Scoping Requirements > 208 Parking Spaces > 208.3 Location
406.5 Accessible Routes, Location
Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking ...
2010 ADA Standards > 4 Accessible Routes > 406 Curb Ramps > 406.5 Location
407.2.1.4 Accessible Routes, Location
The call button that designates the up direction shall be located above the call button that designates the down direction. EXCEPTION ...
2010 ADA Standards > 4 Accessible Routes > 407 Elevators > 407.2 Elevator Landing Requirements > 407.2.1 Call Controls > 407.2.1.4 Location
409.3.2 Accessible Routes, Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1 ...
2010 ADA Standards > 4 Accessible Routes > 409 Private Residence Elevators > 409.3 Elevator Doors > 409.3.2 Location
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING