507.8.1.1 Located Within the Building
JUMP TO FULL CODE CHAPTER
The aggregate floor area of Group H occupancies not located at the perimeter of the building shall not exceed 25 percent of the area limitations for the Group H occupancies as specified in Section 506.
Liquid use, dispensing and mixing rooms having a floor area of not more than 500 square feet (46.5 m2) need not be located on the outer perimeter of the building where they are in accordance with the International Fire Code and NFPA 30.
Liquid storage rooms having a floor area of not more than 1,000 square feet (93 m2) need not be located on the outer perimeter where they are in accordance with the International Fire Code and NFPA 30.
Spray paint booths that comply with the International Fire Code need not be located on the outer perimeter.
Related Code Sections
507.8.1.1 General Building Heights and Areas, Located Within the Building
The aggregate floor area of Group H occupancies not located at the perimeter of the building shall not exceed 25 percent of the area limitations ...
Building Code 2018 of Illinois > 5 General Building Heights and Areas > 507 Unlimited Area Buildings > 507.8 Group H-2, H-3 and H-4 Occupancies > 507.8.1 Allowable Area > 507.8.1.1 Located Within the Building
507.8.1.1 General Building Heights and Areas, Located Within the Building
The aggregate floor area of Group H occupancies not located at the perimeter of the building shall not exceed 25 percent of the area limitations ...
Building Code 2021 of Illinois > 5 General Building Heights and Areas > 507 Unlimited Area Buildings > 507.8 Group H-2, H-3 and H-4 Occupancies > 507.8.1 Allowable Area > 507.8.1.1 Located Within the Building
507.8.1.1.2 General Building Heights and Areas, Liquid Storage Rooms and Rooms for Flammable or Combustible Liquid Use in Closed Systems
feet (93 m 2 ) need not be located on the outer perimeter where they are in accordance with the International Fire Code and NFPA 30 ...
Building Code 2021 of Illinois > 5 General Building Heights and Areas > 507 Unlimited Area Buildings > 507.8 Group H-2, H-3 and H-4 Occupancies > 507.8.1 Allowable Area > 507.8.1.1 Located Within the Building > 507.8.1.1.2 Liquid Storage Rooms and Rooms for Flammable or Combustible Liquid Use in Closed Systems
1106.1.2 Additions, Location
Storm shelters shall be located within the buildings they serve, or shall be located where the maximum distance of travel from not fewer than one ...
Existing Building Code 2018 of Illinois > 11 Additions > 1106 Storm Shelters > 1106.1 Addition to a Group E Occupancy > 1106.1.2 Location
423.4.2 Special Detailed Requirements Based on Occupancy and Use, Location
Storm shelters shall be located within the buildings they serve or shall be located where the maximum distance of travel from not fewer than one ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 423 Storm Shelters > 423.4 Group E Occupancies > 423.4.2 Location