• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

507.8.1.1 Located Within the Building

Building Code 2018 of Illinois > 5 General Building Heights and Areas > 507 Unlimited Area Buildings > 507.8 Group H-2, H-3 and H-4 Occupancies > 507.8.1 Allowable Area > 507.8.1.1 Located Within the Building
JUMP TO FULL CODE CHAPTER
The aggregate floor area of Group H occupancies not located at the perimeter of the building shall not exceed 25 percent of the area limitations for the Group H occupancies as specified in Section 506.

507.8.1.1.1 Liquid Use, Dispensing and Mixing Rooms

Liquid use, dispensing and mixing rooms having a floor area of not more than 500 square feet (46.5 m2) need not be located on the outer perimeter of the building where they are in accordance with the International Fire Code and NFPA 30.

507.8.1.1.2 Liquid Storage Rooms

Liquid storage rooms having a floor area of not more than 1,000 square feet (93 m2) need not be located on the outer perimeter where they are in accordance with the International Fire Code and NFPA 30.

507.8.1.1.3 Spray Paint Booths

Spray paint booths that comply with the International Fire Code need not be located on the outer perimeter.

Related Code Sections


507.8.1.1 General Building Heights and Areas, Located Within the Building
The aggregate floor area of Group H occupancies not located at the perimeter of the building shall not exceed 25 percent of the area limitations ...
Building Code 2018 of Illinois > 5 General Building Heights and Areas > 507 Unlimited Area Buildings > 507.8 Group H-2, H-3 and H-4 Occupancies > 507.8.1 Allowable Area > 507.8.1.1 Located Within the Building
507.8.1.1 General Building Heights and Areas, Located Within the Building
The aggregate floor area of Group H occupancies not located at the perimeter of the building shall not exceed 25 percent of the area limitations ...
Building Code 2021 of Illinois > 5 General Building Heights and Areas > 507 Unlimited Area Buildings > 507.8 Group H-2, H-3 and H-4 Occupancies > 507.8.1 Allowable Area > 507.8.1.1 Located Within the Building
507.8.1.1.2 General Building Heights and Areas, Liquid Storage Rooms and Rooms for Flammable or Combustible Liquid Use in Closed Systems
feet (93 m 2 ) need not be located on the outer perimeter where they are in accordance with the International Fire Code and NFPA 30 ...
Building Code 2021 of Illinois > 5 General Building Heights and Areas > 507 Unlimited Area Buildings > 507.8 Group H-2, H-3 and H-4 Occupancies > 507.8.1 Allowable Area > 507.8.1.1 Located Within the Building > 507.8.1.1.2 Liquid Storage Rooms and Rooms for Flammable or Combustible Liquid Use in Closed Systems
1106.1.2 Additions, Location
Storm shelters shall be located within the buildings they serve, or shall be located where the maximum distance of travel from not fewer than one ...
Existing Building Code 2018 of Illinois > 11 Additions > 1106 Storm Shelters > 1106.1 Addition to a Group E Occupancy > 1106.1.2 Location
423.4.2 Special Detailed Requirements Based on Occupancy and Use, Location
Storm shelters shall be located within the buildings they serve or shall be located where the maximum distance of travel from not fewer than one ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 423 Storm Shelters > 423.4 Group E Occupancies > 423.4.2 Location
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING