Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Table M Load Values Assigned to Fixtures

Illinois Plumbing Code > A Plumbing Materials, Equipment, Use Restrictions and Applicable Standards > M Load Values Assigned to Fixtures
JUMP TO FULL CODE CHAPTER
Fixture
Occupancy
Type of
Supply Control
Load Values in Water (Supply Fixture Units)
Cold
Hot
Total
Water Closet
Public/Private
Flush Valve
10
—
10
Water Closet
Public/Private
Flush Tank
3
—
3
Urinal
Public
1" Flush Valve
10
—
10
Urinal
Public
3/4" Flush Valve
5
—
5
Urinal
Public
Flush Tank
3
—
3
Lavatory
Public
Faucet
1
1
2
Bathtub
Public
Faucet
3
3
4
Shower Head
Public
Mixing Valve
2
2
3
Service Sink
Offices, etc.
Faucet
2
2
3
Kitchen Sink
Hotel/Restaur.
Faucet
3
3
4
Drinking Fountain
Office, etc.
3/8" Valve
0.25
—
0.25
 
 
 
 
 
 
Lavatory
Private
Faucet
0.75
0.75
1
Bathtub
Private
Faucet
1.5
1.5
2
Shower Stall
Private
Mixing Valve
1
1
2
Kitchen Sink
Private
Faucet
1.5
1.5
2
Laundry Trays (1 to 3)
Private
Faucet
2
2
3
 
 
 
 
 
 
Dishwashing Machine
Private
Automatic
 
-1
1
Laundry Machine (8 lb)
Private
Automatic
1.5
1.5
2
 
 
 
 
 
 
Laundry Machine (16 lb)
Public/ General
Automatic
3
3
4

Agency Notes:           For fixtures not listed, loads shall be assumed by comparing the fixtures to one listed using water in similar quantities and at similar rates. The assigned loads for fixtures with both cold and hot water supplies are given for separate cold and hot water loads and for total load.

Where a unit of local government or the community public water supply does not require separate water service lines for irrigation or similar systems that are likely to impose continuous demands (e.g., lawn sprinkler or air conditioning systems), the following rule applies: estimate the continuous demand (in gallons per minute) for outlets/systems separately from the intermittent demand from the fixtures listed in this table, and add this amount to the demand of the fixtures (in gallons per minute).

Fire sprinkler systems are exempt from this table.

(Source: Amended at 38 Ill. Reg. 9940, effective April 24, 2014)

Related Code Sections


Table M Plumbing Materials, Equipment, Use Restrictions and Applicable Standards, Load Values Assigned to Fixtures
Fixture Occupancy Type of Supply Control Load Values in Water (Supply Fixture Units) Cold Hot Total ...
Illinois Plumbing Code > A Plumbing Materials, Equipment, Use Restrictions and Applicable Standards > M Load Values Assigned to Fixtures
Section 890.1330 Drainage System, Drainage Fixture Units (DFUs)
Values for Fixtures. Drainage fixture units (DFUs) (see Appendix A.Table E) designate the relative load of different kinds of fixtures that shall ...
Illinois Plumbing Code > J Drainage System > 890.1330 Drainage Fixture Units (DFUs)
1613.2 Structural Design, Seismic Ground Motion Values
Seismic ground motion values shall be determined in accordance with this section ...
Building Code 2018 of Illinois > 16 Structural Design > 1613 Earthquake Loads > 1613.2 Seismic Ground Motion Values
1613.2 Structural Design, Seismic Ground Motion Values
Seismic ground motion values shall be determined in accordance with this section ...
Building Code 2021 of Illinois > 16 Structural Design > 1613 Earthquake Loads > 1613.2 Seismic Ground Motion Values
18.13.5.10.6 Earthquake-Resistant Structures,
For structures assigned to SDC C, D, E, or F, the maximum factored axial load for precast prestressed piles subjected to a combination of earthquake ...
Building Code Requirements for Structural Concrete of Illinois > 18 Earthquake-Resistant Structures > 18.13 Foundations > 18.13.5 Deep Foundations > 18.13.5.10 Precast Concrete Piles > 18.13.5.10.6
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING