1709.3 Load Test Procedures Not Specified
JUMP TO FULL CODE CHAPTER
Where load test procedures are not specified in the applicable referenced standards, the load-bearing and deformation capacity of structural components and assemblies shall be determined on the basis of a test procedure developed by a registered design professional that simulates applicable loading and deformation conditions. For components and assemblies that are not a part of the seismic force-resisting system, the test shall be as specified in Section 1709.3.1. Load tests shall simulate the applicable loading conditions specified in Chapter 16.
The test assembly shall be subjected to an increasing superimposed load equal to not less than two times the superimposed design load. The test load shall be left in place for a period of 24 hours. The tested assembly shall be considered to have successfully met the test requirements if the assembly recovers not less than 75 percent of the maximum deflection within 24 hours after the removal of the test load. The test assembly shall then be reloaded and subjected to an increasing superimposed load until either structural failure occurs or the superimposed load is equal to two and one-half times the load at which the deflection limitations specified in Section 1709.3.2 were reached, or the load is equal to two and one-half times the superimposed design load. In the case of structural components and assemblies for which deflection limitations are not specified in Section 1709.3.2, the test specimen shall be subjected to an increasing superimposed load until structural failure occurs or the load is equal to two and one-half times the desired superimposed design load. The allowable superimposed design load shall be taken as the lesser of:
- The load at the deflection limitation given in Section 1709.3.2.
- The failure load divided by 2.5.
- The maximum load applied divided by 2.5.
The deflection of structural members under the design load shall not exceed the limitations in Section 1604.3.
Related Code Sections
1709.3 Special Inspections and Tests, Load Test Procedures Not Specified
Where load test procedures are not specified in the applicable referenced standards, the load-bearing and deformation capacity of structural ...
Building Code 2018 of Utah > 17 Special Inspections and Tests > 1709 Preconstruction Load Tests > 1709.3 Load Test Procedures Not Specified
1709.3 Special Inspections and Tests, Load Test Procedures Not Specified
Where load test procedures are not specified in the applicable referenced standards, the load-bearing and deformation capacity of structural ...
Building Code 2015 of Utah > 17 Special Inspections and Tests > 1709 Preconstruction Load Tests > 1709.3 Load Test Procedures Not Specified
1708.2.2 Special Inspections and Tests, Load Test Procedure Not Specified
In the absence of applicable load test procedures contained within a material standard referenced by this code or acceptance criteria for a specific ...
Building Code 2018 of Utah > 17 Special Inspections and Tests > 1708 In-Situ Load Tests > 1708.2 In-Situ Load Tests > 1708.2.2 Load Test Procedure Not Specified
1708.3.2 Special Inspections and Tests, Load Test Procedure Not Specified
In the absence of applicable load test procedures contained within a standard referenced by this code or acceptance criteria for a specific material ...
Building Code 2015 of Utah > 17 Special Inspections and Tests > 1708 In-Situ Load Tests > 1708.3 In-Situ Load Tests > 1708.3.2 Load Test Procedure Not Specified
1709.2 Special Inspections and Tests, Load Test Procedures Specified
Where specific load test procedures, load factors and acceptance criteria are included in the applicable referenced standards, such test procedures ...
Building Code 2018 of Utah > 17 Special Inspections and Tests > 1709 Preconstruction Load Tests > 1709.2 Load Test Procedures Specified