• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3507.3.1 Listing or Approval for Intended Use

NYC Fire Code 2014 > 35 Flammable Gases > 3507 Metal Hydride Hydrogen Storage Systems > 3507.3 Design Requirements > 3507.3.1 Listing or Approval for Intended Use
JUMP TO FULL CODE CHAPTER
Metal hydride hydrogen storage systems shall either be listed for the purpose for which they are used or be of the type for which a certificate of approval has been issued.

Related Code Sections


§28-113.2 Administration, Use of Materials
Whenever this code or the rules of the department requires the use of an approved material, such material shall not be used without the prior approval ...
NYC General Admin. Provisions 2008 > 1 Administration > 113 Materials > §28-113.2 Use of Materials
§28-113.2 Administration, Use of Materials
Whenever this code or the rules of the department requires the use of an approved material, such material shall not be used without the prior approval ...
NYC General Admin. Provisions 2014 > 1 Administration > 113 Materials > §28-113.2 Use of Materials
§28-113.2 Administration, Use of Materials
Whenever this code or the rules of the department requires the use of an approved material, such material shall not be used without the prior ...
NYC General Admin. Provisions 2022 > 1 Administration > 113 Materials > §28-113.2 Use of Materials
Section 1401 Solar Systems, General
Heat exchangers used in domestic water-heating systems shall be approved for the intended use. The system shall have adequate protection ...
NYC Mechanical Code 2008 > 14 Solar Systems > 1401 General
Section 1401 Solar Systems, General
exchangers used in domestic water-heating systems shall be approved for the intended use. The system shall have adequate protection to ensure ...
NYC Mechanical Code 2022 > 14 Solar Systems > 1401 General
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING