2111.8 Lintel and Throat
JUMP TO FULL CODE CHAPTER
Masonry over a fireplace opening shall be supported by a lintel of noncombustible material. The minimum required bearing length on each end of the fireplace opening shall be 4 inches (102 mm). The fireplace throat or damper shall be located not less than 8 inches (203 mm) above the top of the fireplace opening.
Masonry fireplaces shall be equipped with a ferrous metal damper located not less than 8 inches (203 mm) above the top of the fireplace opening. Dampers shall be installed in the fireplace or at the top of the flue venting the fireplace, and shall be operable from the room containing the fireplace. Damper controls shall be permitted to be located in the fireplace.
Related Code Sections
2111.8 Masonry, Lintel and Throat
Masonry over a fireplace opening shall be supported by a lintel of noncombustible material. The minimum required bearing length on each end ...
2111.8 Masonry, Lintel and Throat
Masonry over a fireplace opening shall be supported by a lintel of noncombustible material. The minimum required bearing length on each end ...
2111A.8 Masonry, Lintel and Throat
Masonry over a fireplace opening shall be supported by a lintel of noncombustible material. The minimum required bearing length on each end ...
R1001.7 Chimneys and Fireplaces, Lintel and Throat
of the fireplace opening shall be 4 inches (102 mm). The fireplace throat or damper shall be located not less than 8 inches (203 mm) above the lintel ...
Los Angeles Residential Code > 10 Chimneys and Fireplaces > R1001 Masonry Fireplaces > R1001.7 Lintel and Throat
R1001.7 Chimneys and Fireplaces, Lintel and Throat
of the fireplace opening shall be 4 inches (102 mm). The fireplace throat or damper shall be located not less than 8 inches (203 mm) above the lintel ...
Los Angeles Residential Code > 10 Chimneys and Fireplaces > R1001 Masonry Fireplaces > R1001.7 Lintel and Throat