1109.6.1 Limited-Use/Limited-Application (LULA) Elevators

NYC Building Code 2014 > 11 Accessibility > 1109 Other Features and Facilities > 1109.6 Elevators > 1109.6.1 Limited-Use/Limited-Application (LULA) Elevators
JUMP TO FULL CODE CHAPTER
buildings bulletin
Linked Resources Available

This section has been clarified by a buildings bulletin issued by the Department of Buildings.

Learn more in the Linked Resources panel on the right.
LULA elevators shall comply with Section 408 (Limited-Use/Limited-Application Elevators) of ICC A117.1 and with Part XXV of ASME A17.1 and shall be limited to a maximum rise of not more than 25 feet (7620 mm) and serving not more than three contiguous levels. In new construction, such LULA elevators shall be permitted:

1. To be a part of the required accessible route where either a wheelchair lift complying with Section 1109.7 is permitted or a private residence elevator complying with Section 409 (Private Residence Elevators) of ICC A117.1 is permitted;

2. To be part of the required accessible route in places of religious services; or

3. In multilevel buildings and facilities not required to have an accessible route pursuant to the exceptions in Section 1104.4.

1109.6.1.1 Prior Code Buildings

In prior code buildings, LULA elevators shall be permitted to be a part of the required accessible route where the total floor area of the entire building is less than 10,000 square feet (929 m2) provided such LULA elevator is limited to a maximum rise of not more than 25 feet, serves not more than three contiguous levels, and elevators are not otherwise required by Chapter 30.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


1109.6.1 Accessibility, Limited-Use/Limited-Application (LULA) Elevators
LULA elevators shall comply with Section 408 (Limited-Use/Limited-Application Elevators) of ICC A117.1 and with Part XXV of ASME A17.1 and shall ...
NYC Building Code 2014 > 11 Accessibility > 1109 Other Features and Facilities > 1109.6 Elevators > 1109.6.1 Limited-Use/Limited-Application (LULA) Elevators
1109.6.1 Accessibility, Limited-Use/Limited-Application (LULA) Elevators
LULA elevators shall comply with Section 408 (Limited-Use/Limited-Application Elevator) of ICC A117.1 and with Part XXV of ASME A17.1 and shall ...
NYC Building Code 2008 > 11 Accessibility > 1109 Other Features and Facilities > 1109.6 Elevators > 1109.6.1 Limited-Use/Limited-Application (LULA) Elevators
3001.3 Elevators and Conveying Systems, Accessibility
to be accessible by Chapter 11; 2. Limited-Use/Limited-Application (LULA) elevators permitted to be installed on an accessible route pursuant to Section ...
NYC Building Code 2014 > 30 Elevators and Conveying Systems > 3001 General > 3001.3 Accessibility
408.4.1 Accessible Routes, Car Dimensions and Doors
(1370 mm) minimum, and a net clear platform area 15 square feet (1.4 m2) minimum. Figure 408.4.1 Limited-Use/Limited-Application (LULA) Elevator Car ...
2010 ADA Standards > 4 Accessible Routes > 408 Limited-Use / Limited-Application Elevators > 408.4 Elevator Cars > 408.4.1 Car Dimensions and Doors
3002.4.2 Elevators and Conveying Systems, Elevator Car to Accommodate Ambulance Stretcher
of such a building. 2. Limited-Use/Limited-Application (LULA) elevators (25 feet maximum rise) ...
NYC Building Code 2014 > 30 Elevators and Conveying Systems > 3002 Hoistway Enclosures > 3002.4 Elevator Required > 3002.4.2 Elevator Car to Accommodate Ambulance Stretcher
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Contact Careers Terms Privacy
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US