[F] 703.2.1 Limitations for Indoor Storage and Use
JUMP TO FULL CODE CHAPTER
Flammable gas cylinders in occupancies regulated by the International Residential Code shall not exceed 250 cubic feet (7.1 m3) at normal temperature and pressure (NTP).
Related Code Sections
703.2.1 Gaseous Hydrogen Systems, Limitations for Indoor Storage and Use
Flammable gas cylinders in occupancies regulated by the International Residential Code shall not exceed 250 cubic feet (7.1 m 3 ) at normal ...
Fuel Gas Code 2018 of Kansas > 7 Gaseous Hydrogen Systems > 703 (IFGC) General Requirements > 703.2 Containers, Cylinders and Tanks > 703.2.1 Limitations for Indoor Storage and Use
6603.1.2 Unstable (Reactive) Materials, Limitations for Indoor Storage and Use by Occupancy
The indoor storage of unstable (reactive) materials shall be in accordance with Sections 6603.1.2.1 through 6603.1.2.5 ...
Fire Code 2018 of Kansas > 66 Unstable (Reactive) Materials > 6603 General Requirements > 6603.1 Quantities Not Exceeding the Maximum Allowable Quantity Per Control Area > 6603.1.2 Limitations for Indoor Storage and Use by Occupancy
5803.1.1 Flammable Gases and Flammable Cryogenic Fluids, Special Limitations for Indoor Storage and Use
Flammable gases shall not be stored or used in Group A, E, I or R occupancies or in offices in Group B occupancies. Exceptions: Cylinders ...
Fire Code 2018 of Kansas > 58 Flammable Gases and Flammable Cryogenic Fluids > 5803 General Requirements > 5803.1 Quantities Not Exceeding the Maximum Allowable Quantity Per Control Area > 5803.1.1 Special Limitations for Indoor Storage and Use
6303.1.1 Oxidizers, Oxidizing Gases and Oxidizing Cryogenic Fluids, Special Limitations for Indoor Storage and Use by Occupancy
The indoor storage and use of oxidizing materials shall be in accordance with Sections 6303.1.1.1 through 6303.1.1.3 ...
Fire Code 2018 of Kansas > 63 Oxidizers, Oxidizing Gases and Oxidizing Cryogenic Fluids > 6303 General Requirements > 6303.1 Quantities Not Exceeding the Maximum Allowable Quantity Per Control Area > 6303.1.1 Special Limitations for Indoor Storage and Use by Occupancy
6203.1.1 Organic Peroxides, Special Limitations for Indoor Storage and Use by Occupancy
The indoor storage and use of organic peroxides shall be in accordance with Sections 6203.1.1.1 through 6203.1.1.4 ...
Fire Code 2018 of Kansas > 62 Organic Peroxides > 6203 General Requirements > 6203.1 Quantities Not Exceeding the Maximum Allowable Quantity Per Control Area > 6203.1.1 Special Limitations for Indoor Storage and Use by Occupancy