407.3 Limitation of Hot Water Temperature for Public Lavatories
JUMP TO FULL CODE CHAPTER
Hot water delivered from public-use lavatories
shall be limited to a maximum temperature of 120°F (49°C)
by a device that is in accordance with ASSE 1070 or CSA
B125.3. The water heater thermostat shall not be considered
a control for meeting this provision.
Related Code Sections
407.3 Plumbing Fixtures and Fixture Fittings, Limitation of Hot Water Temperature for Public Lavatories
Hot water delivered from public-use lavatories
shall be limited to a maximum temperature of 120°F (49°C)
by a device that is in accordance with ASSE ...
California Plumbing Code 2016 > 4 Plumbing Fixtures and Fixture Fittings > 407.0 Lavatories > 407.3 Limitation of Hot Water Temperature for Public Lavatories
407.3 Plumbing Fixtures and Fixture Fittings, Limitation of Hot Water Temperature for Public Lavatories
Hot water delivered from public-use lavatories
shall be limited to a maximum temperature of 120°F (49°C) by a device that complies with ASSE 1070 ...
California Plumbing Code 2019 > 4 Plumbing Fixtures and Fixture Fittings > 407.0 Lavatories > 407.3 Limitation of Hot Water Temperature for Public Lavatories
601.2 Water Supply and Distribution, Hot and Cold Water Required
purposes. This requirement shall not
supersede the requirements for individual temperature control
limitations for public lavatories and public ...
California Plumbing Code 2016 > 6 Water Supply and Distribution > 601.0 General > 601.2 Hot and Cold Water Required
601.2 Water Supply and Distribution, Hot and Cold Water Required
for bathing and washing purposes.
This requirement shall not supersede the requirements
for individual temperature control limitations for public lavatories ...
California Plumbing Code 2019 > 6 Water Supply and Distribution > 601.0 General > 601.2 Hot and Cold Water Required
3116B.4 [DPH] Public Pools, Water Supply
A means to limit the hot water to 110°F (43°C) maximum shall be provided to prevent scalding. This temperature ...