37-743 Lighting and Electrical Power
JUMP TO FULL CODE CHAPTER
Public plazas shall be illuminated to provide for safe use and enjoyment of all areas of the public plaza. Special attention should be provided in lighting steps and other changes in elevation and areas under tree canopies and permitted canopies within the public plaza.
Public plazas shall be illuminated with a minimum level of illumination of not less than two horizontal foot candles (lumens per foot) throughout all walkable and sitting areas, including sidewalks directly adjacent to the public plaza, and a minimum level of illumination of not less than 0.5 horizontal foot candles (lumens per foot) throughout all other areas. All lighting sources used to satisfy this illumination requirement shall be located outdoors on the subject zoning lot. Such level of illumination shall be maintained from one hour before sunset to one hour after sunrise, including public plazas that are authorized to close at night. A lighting schedule, including fixtures, wattage and their locations and designs together with a diagram of light level distribution, with light levels indicated at intervals of no more than every 20 square feet, shall be part of the required detailed design plans. Electrical power shall be supplied by one or more outlets furnishing a total of at least 1,200 watts of power for every 4,000 square feet, or fraction thereof, of the area of a public plaza.
All lighting sources that illuminate the public plaza and are mounted on or located within buildings adjacent to the public plaza shall be shielded from direct view. In addition, all lighting within the public plaza area shall be shielded to minimize any adverse effect on surrounding residences.
Related Code Sections
Appendix A Selected Rules of the Department of Buildings [PDF] (page 115)
of wiring and appliances for electrical, [sic] light, heat and power in or on buildings as set forth in New York City Administrative Code ยง27-3010. In ...
22.34.1.3 Special Occupancy Requirements,
alarm indicators shall be activated at the chamber operator's console. All ungrounded electrical leads for power and lighting circuits contained ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 22 Special Occupancy Requirements > 22.34 Hypobaric Facilities > 22.34.1 Design Requirements > 22.34.1.3
702 Communication Elements and Features, Alarms
by a commercial light and power source, be permanently connected to the wiring of the premises electric system, and be permanently installed ...
Accessible and Usable Buildings and Facilities 2009 of New York City > 7 Communication Elements and Features > 702 Alarms
5.8.1.6 Special Application Elevators, Illumination of Cars
Elevators used primarily for the movement of personnel shall have the electrical power meet the requirements of IEEE 45 with car enclosure lighting ...
Safety Code for Elevators and Escalators 2013 of New York City > 5 Special Application Elevators > 5.8 Marine Elevators > 5.8.1 Electric Marine Elevators > 5.8.1.6 Illumination of Cars
2702.2.20.1 Electrical, Equipment Requiring Emergency Power System
with an emergency power system: Exit signs and means of egress illumination required by Chapter 10; Elevator car lighting; Emergency voice/alarm ...
NYC Building Code 2008 > 27 Electrical > 2702 Emergency and Standby Power Systems > 2702.2 Where Required > 2702.2.20 Occupancy Groups B, E and R-1 > 2702.2.20.1 Equipment Requiring Emergency Power System