*§28-424.1 Lift Director Required
JUMP TO FULL CODE CHAPTER
It shall be unlawful for a crane or derrick that requires or possesses a certificate of on-site inspection, or which, in accordance with rules promulgated by the commissioner, is subject to supervision by a licensed master rigger in lieu of a certificate of on-site inspection, to perform any of the following tasks unless a lift director is present at the site during all times when:
- The crane or derrick is picking a load;
- The crane is traveling at the site, including but not limited to being moved onto or off of cribbing or up or down a ramp;
- The crane or derrick is being placed into a parked condition or otherwise being taken out of service;
- The crane's or derrick's boom/jib is being laid down or jackknifed;
- The crane's or derrick's boom/jib is being raised from a laid down or jackknifed position; or
- Other special protective measures for wind are being installed or removed.
Exception: The requirement for a lift director does not apply to the assembly or disassembly of a crane or derrick, nor to the use of an assist crane or derrick during assembly/disassembly, provided an assembly/disassembly director is supervising the assembly/disassembly operation in accordance with rules promulgated by the commissioner.
Related Code Sections
*§28-424.1 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work, Lift Director Required
or removed.
Exception : The requirement for a lift director does not apply to the assembly or disassembly of a crane or derrick, nor ...
NYC General Admin. Provisions 2014 > 4 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work > *424 Lift Director Registration > *§28-424.1 Lift Director Required
*3319.2.3 Safeguards During Construction or Demolition, Lift Directors
Lift directors shall be designated, and perform the duties assigned to them, in accordance with rules promulgated by the commissioner ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3319 Cranes and Derricks > *3319.2 Personnel > *3319.2.3 Lift Directors
*§28-309.6 Maintenance of Buildings, Suspension
The director of the office of long-term planning and sustainability may suspend all or part of the requirement to benchmark pursuant to this article ...
NYC General Admin. Provisions 2008 > 3 Maintenance of Buildings > 309 *Benchmarking Energy and Water Use > *§28-309.6 Suspension
§28-309.6 Maintenance of Buildings, Suspension
The director of the office of long-term planning and sustainability may suspend all or part of the requirement to benchmark pursuant to this article ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 309 Benchmarking Energy and Water Use and Disclosure of Energy Efficiency Scores and Grades > §28-309.6 Suspension
§28-406.3.1 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work, Director
Each laboratory shall have in responsible charge a director who shall be a registered design professional and who shall personally
supervise all ...
NYC General Admin. Provisions 2008 > 4 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work > 406 Concrete Testing Laboratory License > §28-406.3 Additional Requirements > §28-406.3.1 Director