R310.1.5.1 Licensed Facilities
JUMP TO FULL CODE CHAPTER
Windows in rooms used for foster care or day care licensed or registered by the state of Minnesota shall comply with the provisions of Section R310.1.5, or all of the following conditions, whichever is more restrictive:
- Minimum of 20 inches (508 mm) in clear opening width;
- Minimum of 20 inches (508 mm) in clear opening height;
- Minimum of 648 square inches (4.5 square feet) clear opening; and
- Maximum of 48 inches (1219 mm) from the floor to the sill height.
Related Code Sections
1029.6.1 Means of Egress, Licensed Facilities
Windows in rooms used for foster care or day care licensed or registered by the state of Minnesota shall comply with the provisions of Section 1029.6 ...
Minnesota Fire Code 2015 > 10 Means of Egress > 1029 Emergency Escape and Rescue > 1029.6 Replacement Windows > 1029.6.1 Licensed Facilities
1029.6.1 Means of Egress, Licensed Facilities
Windows in rooms used for foster care or day care licensed or registered by the state of Minnesota shall comply with the provisions of Section 1029.6 ...
Minnesota Building Code 2015 > 10 Means of Egress > 1029 Emergency Escape and Rescue > 1029.6 Replacement Windows > 1029.6.1 Licensed Facilities
R310.1.5.1 Building Planning, Licensed Facilities
Windows in rooms used for foster care or day care licensed or registered by the state of Minnesota shall comply with the provisions of Section ...
Minnesota Residential Code 2015 > 3 Building Planning > R310 Emergency Escape and Rescue Openings > R310.1 Emergency Escape and Rescue Required > R310.1.5 Replacement Windows > R310.1.5.1 Licensed Facilities
903.2.8.2 Fire Protection Systems, State-Licensed Facilities
Group R-3 or R-4 occupancies containing facilities licensed by Minnesota shall be provided with an automatic sprinkler system as required ...
Minnesota Fire Code 2015 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.8 Group R > 903.2.8.2 State-Licensed Facilities
903.2.8.2 Fire Protection Systems, State Licensed Facilities
Group R-3 or R-4 occupancies containing facilities licensed by the state of Minnesota shall be provided with an automatic sprinkler system ...
Minnesota Building Code 2015 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.8 Group R > 903.2.8.2 State Licensed Facilities