Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

24-32 Level of Yards and Measurement of Yard Width or Depth

NYC Zoning Resolution > II Residence District Regulations > 4 - Bulk Regulations for Community Facilities in Residence Districts > 24-30 Yard Regulations > 24-32 Level of Yards and Measurement of Yard Width or Depth
JUMP TO FULL CODE CHAPTER

In all Residence Districts, the level of a yard or of a rear yard equivalent shall not be higher than curb level, except that natural grade level need not be disturbed in order to comply with this requirement. No building or other structure shall be erected above ground level in any required yard or rear yard equivalent, except as otherwise provided in Section 24-33 (Permitted Obstructions in Required Yards or Rear Yard Equivalents).

In all Residence Districts, the width or depth of a yard or rear yard equivalent shall be measured perpendicular to lot lines.

Related Code Sections


1206.2 Interior Environment, Yards
Yards shall not be less than the dimensions prescribed by the Zoning Resolution of the City of New York and other applicable laws, rules ...
NYC Building Code 2008 > 12 Interior Environment > 1206 Yards and Courts > 1206.2 Yards
1206.2 Interior Environment, Yards
Yards shall not be less than the dimensions prescribed by the New York City Zoning Resolution and other applicable laws, rules, and regulations ...
NYC Building Code 2014 > 12 Interior Environment > 1206 Yards and Courts > 1206.2 Yards
§27-739 Light, Heat, Ventilation and Noise Control, Yards and Courts
one foot candle measured at the lower level or levels of all yards or courts ...
NYC 1968 Code (Vol I) > 12 Light, Heat, Ventilation and Noise Control > 4 Standards of Artificial Light > §27-739 Yards and Courts
1205.2.2 Interior Environment, Adjoining Spaces
complies with Section 1206; The maximum depth of any habitable room is 30 feet (9144 mm) measured from the outer face of the exterior wall forming ...
NYC Building Code 2008 > 12 Interior Environment > 1205 Lighting > 1205.2 Natural Light > 1205.2.2 Adjoining Spaces
1205.2.2 Interior Environment, Adjoining Spaces
with Section 1206; The maximum depth of any habitable room is 30 feet (9144 mm) measured from the outer face of the exterior wall forming ...
NYC Building Code 2014 > 12 Interior Environment > 1205 Lighting > 1205.2 Natural Light > 1205.2.2 Adjoining Spaces
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE