1132A.4 Level Floor or Landing
JUMP TO FULL CODE CHAPTER
See also Chapter 10. The floor or landing on each side of a door shall be level. Primary entry doors, required exit doors or secondary exterior doors with changes in height between the interior surface or floor level and the exterior surface or floor level shall comply with the following:
- Exterior landings of impervious construction (e.g., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than 1/2 inch (12.7 mm) of change in height between floor surfaces. Changes in level shall comply with Section 1131A.
- Exterior landings of pervious construction (e.g., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than 1/2 inch (12.7 mm) of change in height between floor surfaces. Changes in level shall comply with Section 1131A.
- Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 4 inches (101.6 mm). Changes in height greater than 1/2 inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 1114A or by means of a platform constructed to the level of the floor as illustrated in Figure 11A-8J.
- Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 1 inch (25.4 mm), provided a ramp with a maximum slope of 1:8 is permanently installed. (See Figure 11A-8K.)
- In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to 1/4 inch (6.35 mm) per foot (12 inches) (305 mm), in a direction away from the primary entrance of the dwelling unit for drainage.
Thresholds at the primary entry and required exit doors shall be no higher than 1/2 inch (12.7 mm). Thresholds at secondary exterior doors, including sliding door tracks, shall be no higher than 3/4 inch (19.05 mm). Changes in height at interior door thresholds (e.g., floor material changes at door thresholds) shall not exceed 1/2 inch (12.7 mm). Thresholds shall comply with the following:
Related Code Sections
1126A.2 Housing Accessibility, Level Floor or Landing
The floor or landing on each side of an exit door or gate shall be level. (See Chapter 10 ...
Los Angeles Building Code > 11A Housing Accessibility > 1126A Doors, Gates and Windows > 1126A.2 Level Floor or Landing
1132A.4 Housing Accessibility, Level Floor or Landing
See also Chapter 10. The floor or landing on each side of a door shall be level. Primary entry doors, required exit doors or secondary exterior doors ...
Los Angeles Building Code > 11A Housing Accessibility > 1132A Doors > 1132A.4 Level Floor or Landing
1126A.3 Housing Accessibility, Maneuvering Clearances
with front approach: Pull side approach. The level floor or landing shall extend in the direction of the door or gate swing at least 60 inches (1524 mm ...
Los Angeles Building Code > 11A Housing Accessibility > 1126A Doors, Gates and Windows > 1126A.3 Maneuvering Clearances
1126A.3.2 Housing Accessibility, Swinging Doors and Gates
The following provisions shall apply to swinging doors or gates with front approach: Pull side approach. The level floor or landing shall extend ...
Los Angeles Building Code > 11A Housing Accessibility > 1126A Doors, Gates and Windows > 1126A.3 Maneuvering Clearances > 1126A.3.2 Swinging Doors and Gates
1126A.3.2.3 Housing Accessibility, Latch Side Approach
approach shall have a level floor or landing not less than 60 inches (1524 mm) in depth, and shall be provided with a clear and level area extending ...
Los Angeles Building Code > 11A Housing Accessibility > 1126A Doors, Gates and Windows > 1126A.3 Maneuvering Clearances > 1126A.3.2 Swinging Doors and Gates > 1126A.3.2.3 Latch Side Approach