• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R602.10.4.3 Length of Bracing for Continuous Sheathing

Residential Code 2009 > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.4 Continuous Sheathing > R602.10.4.3 Length of Bracing for Continuous Sheathing
JUMP TO FULL CODE CHAPTER
Braced wall lines with continuous sheathing shall be provided with braced wall panels in the length required in Tables R602.10.1.2(1) and R602.10.1.2(2). Only those full-height braced wall panels complying with the length requirements of Table R602.10.4.2 shall be permitted to contribute to the minimum required length of bracing.

Related Code Sections


R602.10.4.3 Wall Construction, Length of Bracing for Continuous Sheathing
Braced wall lines with continuous sheathing shall be provided with braced wall panels in the length required in Tables R602.10.1.2(1 ...
Residential Code 2009 > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.4 Continuous Sheathing > R602.10.4.3 Length of Bracing for Continuous Sheathing
R602.10.4.1 Wall Construction, Mixing Methods
be permitted to be used along a braced wall line with continuous sheathed methods, provided that the length of required bracing for that braced wall line ...
Residential Code 2018 > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.4 Construction Methods for Braced Wall Panels > R602.10.4.1 Mixing Methods
R602.10.4.1 Wall Construction, Mixing Methods
Mixing of bracing methods shall be permitted as follows: Mixing intermittent bracing and continuous sheathing methods from story to story shall ...
Residential Code 2015 > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.4 Construction Methods for Braced Wall Panels > R602.10.4.1 Mixing Methods
R602.10.4.1 Wall Construction, Mixing Methods
with continuous sheathing methods CS-WSP, CS-G and CS-PF along the exterior portion of the same braced wall line shall be permitted. The length ...
Residential Code 2012 > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.4 Construction Methods for Braced Wall Panels > R602.10.4.1 Mixing Methods
R602.10.1.1 Wall Construction, Braced Wall Panels
that continuous sheathing methods shall conform to the additional requirements of Sections R602.10.4 and R602.10.5. Mixing bracing methods within a braced wall ...
Residential Code 2009 > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.1 Braced Wall Lines > R602.10.1.1 Braced Wall Panels
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE