R507.2.3 Ledger to Band Joist Fastener Details

Residential Code 2015 of Utah > 5 Floors > R507 EXTERIOR DECKS > R507.2 Deck Ledger Connection to Band Joist > R507.2.3 Ledger to Band Joist Fastener Details
JUMP TO FULL CODE CHAPTER
Fasteners used in deck ledger connections in accordance with Table R507.2 shall be hot-dipped galvanized or stainless steel and shall be installed in accordance with Table R507.2.1 and Figures R507.2.1(1) and R507.2.1(2).


For SI: 1 inch = 25.4 mm.


FIGURE 507.2.3(1) DECK ATTACHMENT FOR LATERAL LOADS


For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.


FIGURE R507.2.3(2) DECK ATTACHMENT FOR LATERAL LOADS
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


R507.2.3 Floors, Ledger to Band Joist Fastener Details
Fasteners used in deck ledger connections in accordance with Table R507.2 shall be hot-dipped galvanized or stainless steel and shall be installed ...
Residential Code 2015 of Utah > 5 Floors > R507 EXTERIOR DECKS > R507.2 Deck Ledger Connection to Band Joist > R507.2.3 Ledger to Band Joist Fastener Details
2308.4.2.3 Wood, Framing Details
, band or rim joist or to an adjoining stud or by other means. Solid blocking shall be not less than 2 inches (51 mm) in thickness and the full depth ...
Building Code 2015 of Utah > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.4 Floor Framing > 2308.4.2 Floor Joists > 2308.4.2.3 Framing Details
2308.4.2.3 Wood, Framing details
, band or rim joist or to an adjoining stud or by other means. Solid blocking shall be not less than 2 inches (51 mm) in thickness and the full depth ...
Building Code 2018 of Utah > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.4 Floor framing > 2308.4.2 Floor joists > 2308.4.2.3 Framing details
2304.10.1 Wood, Fastener Requirements
BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER SPACING AND LOCATION Roof 1. Blocking between ceiling joists, rafters or trusses ...
Building Code 2015 of Utah > 23 Wood > 2304 General Construction Requirements > 2304.10 Connectors and Fasteners > 2304.10.1 Fastener Requirements
2304.10.1 Wood, Fastener requirements
ELEMENTS NUMBER AND TYPE OF FASTENER SPACING AND LOCATION Roof 1. Blocking between ceiling joists, rafters or trusses to top ...
Building Code 2018 of Utah > 23 Wood > 2304 General Construction Requirements > 2304.10 Connectors and fasteners > 2304.10.1 Fastener requirements
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Free Law Contact Careers Terms Privacy Press Kit
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US