1926.501(b)(2) Leading Edges
JUMP TO FULL CODE CHAPTER
Each employee who is constructing a leading edge 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, or personal fall arrest systems. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.
Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.
Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.
Each employee on a walking/working surface 6 feet (1.8 m) or more above a lower level where leading edges are under construction, but who is not engaged in the leading edge work, shall be protected from falling by a guardrail system, safety net system, or personal fall arrest system. If a guardrail system is chosen to provide the fall protection, and a controlled access zone has already been established for leading edge work, the control line may be used in lieu of a guardrail along the edge that parallels the leading edge.
Related Code Sections
1926.501(b)(2) Fall Protection, Leading Edges
Each employee who is constructing a leading edge 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems ...
OSHA 1926 Construction > M Fall Protection > 1926.501 Duty to Have Fall Protection > 1926.501(b) > 1926.501(b)(2) Leading Edges
1926.502(g)(1) Fall Protection,
When used to control access to areas where leading edge and other operations are taking place the controlled access zone shall be defined ...
OSHA 1926 Construction > M Fall Protection > 1926.502 Fall Protection Systems Criteria and Practices > 1926.502(g) Controlled Access Zones > 1926.502(g)(1)
Subpart R Steel Erection, App D - Illustration of the Use of Control Lines to Demarcate Controlled Decking Zones (CDZs): Non-Mandatory Guidelines for Complying With § 1926.760(C)(3)
When used to control access to areas where leading edge and initial securement of metal deck and other operations connected with leading edge work ...
OSHA 1926 Construction > R Steel Erection > R App D - Illustration of the Use of Control Lines to Demarcate Controlled Decking Zones (CDZs): Non-Mandatory Guidelines for Complying With § 1926.760(C)(3)
1926.760(c) Steel Erection, Controlled Decking Zone (CDZ)
is initially being installed and forms the leading edge of a work area. In each CDZ, the following shall apply ...
OSHA 1926 Construction > R Steel Erection > 1926.760 Fall Protection > 1926.760(c) Controlled Decking Zone (CDZ)
1926.760(c)(1) Steel Erection,
Each employee working at the leading edge in a CDZ shall be protected from fall hazards of more than two stories or 30 feet (9.1 m), whichever ...
OSHA 1926 Construction > R Steel Erection > 1926.760 Fall Protection > 1926.760(c) Controlled Decking Zone (CDZ) > 1926.760(c)(1)