424.1.3 Lavatory Operation Without External Electrical Power
JUMP TO FULL CODE CHAPTER
Where automatic lavatory faucets connected to an external supply of electrical power and provided in a bathroom or toilet room, at least one lavatory faucet in such bathroom or toilet room shall be capable of normal operation in the absence of an external supply of electrical power for a period of at least two weeks, either through manual operation or built-in battery back-up. Where such automatic lavatory faucets are located in a bathroom or toilet room with a required accessible lavatory, such operational lavatory faucet shall be at such required accessible lavatory.
Exception: Section 424.1.3 shall not apply to more than one bathroom or toilet room in a dwelling unit.
Related Code Sections
424.1.3 Fixtures, Faucets and Fixture Fittings, Lavatory Operation Without External Electrical Power
faucet in such bathroom or toilet room shall be capable of normal operation in the absence of an external supply of electrical power for a period ...
NYC Plumbing Code 2014 > 4 Fixtures, Faucets and Fixture Fittings > 424 Faucets and Other Fixture Fittings > 424.1 Approval > 424.1.3 Lavatory Operation Without External Electrical Power
425.1.2 Fixtures, Faucets and Fixture Fittings, Water Closet Flushing Without External Electrical Power
Where automatic flushing devices connected to an external supply of electrical power are provided for water closets in a bathroom or toilet room ...
NYC Plumbing Code 2014 > 4 Fixtures, Faucets and Fixture Fittings > 425 Flushing Devices for Water Closets and Urinals > 425.1 Flushing Devices Required > 425.1.2 Water Closet Flushing Without External Electrical Power
3008.9 Elevators and Conveying Systems, Electrical Power
is utilized, the standby power generating equipment need only be sized to satisfy the loads required to simultaneously operate those elevators identified ...
NYC Building Code 2014 > 30 Elevators and Conveying Systems > 3008 Occupant Evacuation Elevators > 3008.9 Electrical Power
3007.8 Elevators and Conveying Systems, Electrical Power
The following features serving each fire service access elevator shall be supplied by both normal power and Type 60/Class 6/Level 1 standby power ...
NYC Building Code 2014 > 30 Elevators and Conveying Systems > 3007 Fire Service Access Elevator > 3007.8 Electrical Power
P102.2 R-2 Occupancy Toilet and Bathing Facilities Requirements, Operable Parts
Lighting controls, electrical switches and receptacle outlets, and environmental controls shall comply with Section 309 of ICC A117.1 ...
NYC Building Code 2008 > P R-2 Occupancy Toilet and Bathing Facilities Requirements > P102 Toilet and Bathing Facilities > P102.2 Operable Parts