L 402.5.1 Lavatory Faucets in Residences, Apartments, and Private Bathrooms in Lodging Facilities, Hospitals, and Patient Care Facilities
Go To Full Code Chapter
The flow rate for lavatory faucets installed in residences, apartments, and private bathrooms in lodging, hospitals, and patient care facilities (including skilled nursing and long-term care facilities) shall not exceed 1.5 gpm (5.7 L/m) at 60 psi (414 kPa) in accordance with ASME A112.18.1/CSA B125.1 and shall be listed to the EPA WaterSense High Efficiency Lavatory Faucet Specification.
Related Code Sections
L 402.5.1 Sustainable Practices, Lavatory Faucets in Residences, Apartments, and Private Bathrooms in Lodging Facilities, Hospitals, and Patient Care Facilities
The flow rate for lavatory faucets installed in residences, apartments, and private bathrooms in lodging, hospitals, and patient care facilities ...
407.0 Plumbing Fixtures and Fixture Fittings, Lavatories
for public lavatory faucets shall not exceed 0.5 gpm at 60 psi (1.9 L/m at 414 kPa) and 2.2 gpm at 60 psi (8.3 L/m at 414 kPa) for private lavatory faucets ...
1109.2 Accessibility, Toilet and Bathing Facilities
of critical care or intensive care patient sleeping rooms serving Accessible units are not required to be accessible. Toilet rooms or bathing rooms designed ...
8.15.8.1 Installation Requirements, Bathrooms
Sprinklers shall be required in bathrooms of limited care facilities and nursing homes, as defined in NFPA 101 ...
517.21 Special Occupancies, Ground-Fault Circuit-Interrupter Protection for Personnel in Category 2 (General Care) and Category 1 (Critical Care) Spaces
Receptacles shall not be required in bathrooms or toilet rooms. [99:6.3.2.2.2(D)] Receptacles located in patient bathrooms and toilet rooms ...