// CODE SNIPPET
11B-809.10.8 Lavatories, Vanities, Mirrors and Towel Bars
Go To Full Code Chapter
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section. Where mirrors or towel bars are provided, no less than one of each shall comply with this section.
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with base cabinets shall be installed with the centerline 24 inches (610 mm) minimum from an adjoining wall or fixture to allow for a parallel approach. The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor.
11B-809.10.8.2 Floor Space
11B-809.10.8.3 Cabinets
11B-809.10.8.4 Knee and Toe Clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
11B-809.10.8.5 Plumbing Protection
Plumbing protection shall comply with Section 11B-809.9.7.
11B-809.10.8.6 Controls
Faucet controls and operating mechanisms shall comply with Section 11B-309.4.
Related Code Sections
11B-809.10.8 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Lavatories, Vanities, Mirrors and Towel Bars
Bathing rooms or powder rooms required to comply with
Section 11B-809.10 shall provide lavatories complying with
this section. Where mirrors or towel ...
11B-809.10.8 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Lavatories, Vanities, Mirrors and Towel Bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section. Where mirrors or towel ...
11B-809.10.8.5 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Plumbing Protection
Plumbing protection shall comply with Section 11B-809.9.7 ...
California Building Code 2022 > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-809 Residential Dwelling Units > 11B-809.10 Toilet and Bathing Rooms > 11B-809.10.8 Lavatories, Vanities, Mirrors and Towel Bars > 11B-809.10.8.5 Plumbing Protection
11B-809.10.8.6 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Controls
Faucet controls and operating mechanisms shall comply with Section 11B-309.4 ...
11B-809.10.8.7 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Mirrors and Towel Bars
Where mirrors are provided the bottom edge of the reflective surface shall be 40 inches (1016 mm) maximum above the
finish floor. Where towel bars ...
California Building Code 2019 > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-809 Residential Dwelling Units > 11B-809.10 Toilet and Bathing Rooms > 11B-809.10.8 Lavatories, Vanities, Mirrors and Towel Bars > 11B-809.10.8.7 Mirrors and Towel Bars