P2706.1.2.1 Laundry Tray Connection to Standpipe
JUMP TO FULL CODE CHAPTER
Where a laundry tray waste line connects into a standpipe for an automatic clothes washer drain, the standpipe shall extend not less than 30 inches (762 mm) above the standpipe trap weir and shall extend above the flood level rim of the laundry tray. The outlet of the laundry tray shall not be greater than 30 inches (762 mm) horizontally from the standpipe trap.
Related Code Sections
P2706.1.2.1 Plumbing Fixtures, Laundry Tray Connection to Standpipe
Where a laundry tray waste line connects into a standpipe for an automatic clothes washer drain, the standpipe shall extend not less than 30 inches ...
2017 FBC - Residential, 6th edition > 27 Plumbing Fixtures > P2706 Waste Receptors > P2706.1 General > P2706.1.2 Standpipes > P2706.1.2.1 Laundry Tray Connection to Standpipe
P2706.1.2.1 Plumbing Fixtures, Laundry Tray Connection to Standpipe
Where a laundry tray waste line connects into a standpipe for an automatic clothes washer drain, the standpipe shall extend not less than 30 inches ...
2020 FBC - Residential, 7th edition > 27 Plumbing Fixtures > P2706 Waste Receptors > P2706.1 General > P2706.1.2 Standpipes > P2706.1.2.1 Laundry Tray Connection to Standpipe
802.4.3.1 Indirect/Special Waste, Connection of Laundry Tray to Standpipe
As an alternative for a laundry tray fixture connecting directly to a drainage system, a laundry tray waste line without a fixture trap shall connect ...
2020 FBC - Plumbing, 7th edition > 8 Indirect/Special Waste > 802 Indirect Wastes > 802.4 Waste Receptors > 802.4.3 Standpipes > 802.4.3.1 Connection of Laundry Tray to Standpipe
P2706.2.1 Plumbing Fixtures, Laundry Tray Connection
A laundry tray waste line is permitted to connect into a standpipe for the automatic clothes washer drain. The standpipe shall extend not less than ...
2014 FBC - Residential, 5th edition > 27 Plumbing Fixtures > P2706 Waste Receptors > P2706.2 Standpipes > P2706.2.1 Laundry Tray Connection
P2706.1 Plumbing Fixtures, General
Where a laundry tray waste line connects into a standpipe for an automatic clothes washer drain, the standpipe shall ...
2017 FBC - Residential, 6th edition > 27 Plumbing Fixtures > P2706 Waste Receptors > P2706.1 General