1926.1416(d)(3)(ii) Lattice Boom Cranes
JUMP TO FULL CODE CHAPTER
Lattice boom cranes manufactured after Feb 28, 1992, must be equipped with a device that either automatically prevents damage and load failure from contact between the load block, overhaul ball, or similar component, and the boom tip (or fixed upper block or similar component), or warns the operator in time for the operator to prevent two-blocking. The device must prevent such damage/failure or provide adequate warning for all points where two-blocking could occur.
Lattice boom cranes and derricks manufactured after November 8, 2011 must be equipped with a device which automatically prevents damage and load failure from contact between the load block, overhaul ball, or similar component, and the boom tip (or fixed upper block or similar component). The device(s) must prevent such damage/failure at all points where two-blocking could occur.
The requirements in paragraphs (d)(3)(ii)(A) and (B) of this section do not apply to such lattice boom equipment when used for dragline, clamshell (grapple), magnet, drop ball, container handling, concrete bucket, marine operations that do not involve hoisting personnel, and pile driving work.
Clearly mark the cable (so that it can easily be seen by the operator) at a point that will give the operator sufficient time to stop the hoist to prevent two-blocking, or use a spotter.
Related Code Sections
1926.1416(d)(3)(ii) Cranes & Derricks in Construction, Lattice Boom Cranes
Lattice boom cranes manufactured after Feb 28, 1992, must be equipped with a device that either automatically prevents damage and load failure from ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1416 Operational Aids > 1926.1416(d) Category I Operational Aids and Alternative Measures > 1926.1416(d)(3) Anti Two-Blocking Device > 1926.1416(d)(3)(ii) Lattice Boom Cranes
1926.6(dd)(18) General,
SAE J987 (rev. Jun. 2003), Lattice Boom Cranes-Method of Test, revised Jun. 2003 ("SAE J987 (Jun. 2003)"), IBR approved for §1926.1433(c) ...
OSHA 1926 Construction > A General > 1926.6 Incorporation by Reference > 1926.6(dd) > 1926.6(dd)(18)
1926.1431(p)(2) Cranes & Derricks in Construction,
For lattice boom cranes: Clearly mark the cable (so that it can easily be seen by the operator) at a point that will give the operator sufficient ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(p) Hoisting Personnel for Pile Driving Operations > 1926.1431(p)(2)
1926.1416(d) Cranes & Derricks in Construction, Category I Operational Aids and Alternative Measures
Telescopic boom cranes ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1416 Operational Aids > 1926.1416(d) Category I Operational Aids and Alternative Measures
1926.1431(p) Cranes & Derricks in Construction, Hoisting Personnel for Pile Driving Operations
For lattice boom cranes: Clearly mark the cable (so that it can easily be seen ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(p) Hoisting Personnel for Pile Driving Operations