R703.7.1 Lath
JUMP TO FULL CODE CHAPTER
Lath and lath attachments shall be of corrosion-resistant materials. Expanded metal or woven wire lath shall be attached with 11/2-inch-long (38 mm), 11 gage nails having a 7/16-inch (11.1 mm) head, or 7/8-inch-long (22.2 mm), 16 gage staples, spaced not more than 6 inches (152 mm), or as otherwise approved.
Related Code Sections
1404.10.1.4.1 Exterior Walls, Lathing
Lathing shall comply with the requirements of Section 2510 ...
Los Angeles Building Code > 14 Exterior Walls > 1404 Installation of Wall Coverings > 1404.10 Adhered Masonry Veneer > 1404.10.1 Exterior Adhered Masonry Veneer > 1404.10.1.4 Adhered Masonry Veneer Installed With Lath and Mortar > 1404.10.1.4.1 Lathing
1405.10.1.4.1 Exterior Walls, Lathing
Lathing shall comply with the requirements of Section 2510 ...
Los Angeles Building Code > 14 Exterior Walls > 1405 Installation of Wall Coverings > 1405.10 Adhered Masonry Veneer > 1405.10.1 Exterior Adhered Masonry Veneer > 1405.10.1.4 Adhered Masonry Veneer Installed With Lath and Mortar > 1405.10.1.4.1 Lathing
R703.7.1 Wall Covering, Lath
Lath and lath attachments shall be of corrosion-resistant materials. Expanded metal or woven wire lath shall be attached with 1 1 / 2 -inch-long (38 ...
Los Angeles Residential Code > 7 Wall Covering > R703 Exterior Covering > R703.7 Exterior Plaster > R703.7.1 Lath
R703.7.1 Wall Covering, Lath
Lath and lath attachments shall be of corrosion-resistant materials. Expanded metal or woven wire lath shall be attached with 1 1 / 2 -inch-long (38 ...
Los Angeles Residential Code > 7 Wall Covering > R703 Exterior Covering > R703.7 Exterior Plaster (Stucco) > R703.7.1 Lath
Section 2507 Gypsum Board, Gypsum Panel Products and Plaster, Lathing and Plastering
Lathing and plastering materials and accessories shall be marked by the manufacturer's designation to indicate compliance with the appropriate ...
Los Angeles Building Code > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2507 Lathing and Plastering