[BS] 405A.2.4.1 Lateral Force-Resisting Elements
JUMP TO FULL CODE CHAPTER
Regardless of the level of damage to vertical elements of the lateral force-resisting system, if substantial structural damage to gravity load-carrying components was caused primarily by wind or seismic effects, then the building shall be evaluated in accordance with Section 405A.2.3.1 and, if noncompliant, rehabilitated in accordance with Section 405A.2.3.3.
Related Code Sections
3405A.3.1 Existing Structures, Lateral Force-Resisting Elements
Regardless of the level of damage to vertical elements of the lateral force-resisting system, if substantial structural damage to gravity load ...
California Building Code 2016 (Vol 1 & 2) > 34A Existing Structures > 3405A Repairs > 3405A.3 Substantial Structural Damage to Gravity Load- Carrying Components > 3405A.3.1 Lateral Force-Resisting Elements
404.3.1 Prescriptive Compliance Method, Lateral Force-Resisting Elements
Regardless of the level of damage to vertical elements of the lateral force-resisting system, if substantial structural damage to gravity load ...
California Existing Building Code 2016 > 4 Prescriptive Compliance Method > 404 Repairs > 404.3 Substantial Structural Damage to Gravity Load-Carrying Components > 404.3.1 Lateral Force-Resisting Elements
405.2.4.1 Repairs, Lateral Force-Resisting Elements
Regardless of the level of damage to vertical elements of the lateral force-resisting system, if substantial structural damage to gravity load ...
California Existing Building Code 2019 > 4 Repairs > 405 Structural > 405.2 Repairs to Damaged Buildings > 405.2.4 Substantial Structural Damage to Gravity Load-Carrying Components > 405.2.4.1 Lateral Force-Resisting Elements
405A.2.4.1 Repairs, Lateral Force-Resisting Elements
Regardless of the level of damage to vertical elements of the lateral force-resisting system, if substantial structural damage to gravity load ...
California Existing Building Code 2019 > 4A Repairs > 405A Structural > 405A.2 Repairs to Damaged Buildings > 405A.2.4 Substantial Structural Damage to Gravity Load-Carrying Components > 405A.2.4.1 Lateral Force-Resisting Elements
2508.5.6 Gypsum Board, Gypsum Panel Products and Plaster, Diaphragm Ceiling Connection to Partitions
Connection of diaphragm ceiling to the vertical lateral force resisting elements shall be designed and detailed to transfer lateral forces ...
California Building Code 2016 (Vol 1 & 2) > 25 Gypsum Board, Gypsum Panel Products and Plaster > 2508 Gypsum Construction > 2508.5 Horizontal Gypsum Board or Gypsum Panel Product Diaphragm Ceilings > 2508.5.6 Diaphragm Ceiling Connection to Partitions