The opening in the enclosure shall be guarded by a gate to a height equal to that of the enclosure. The gates shall be permitted to be the horizontally sliding or the swinging type and shall be equipped with a combination mechanical lock and electric contact conforming to 2.12.4 and 5.3.1.8.4 through 5.3.1.8.7 where doors and gates exceed 915 mm (36 in.) in height.
Upcodes Diagrams

Related Code Sections

5.7.8 Special Application Elevators, Hoistway Doors and Gates
The full width of each landing opening shall be protected by doors or gates. The landing opening shall be at least 2030 mm (80 in.) in height. The ...
405.7.5 Accessible Routes, Doorways
Where a door or gate is adjacent to a ramp landing, maneuvering clearances required by Sections 404.2.3 and 404.3.4 shall be permitted to overlap ...