• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section M1303 Labeling of Appliances

Residential Code 2015 of Utah > 13 General Mechanical System Requirements > M1303 Labeling of Appliances
JUMP TO FULL CODE CHAPTER

M1303.1 Label Information

A permanent factory-applied nameplate(s) shall be affixed to appliances on which shall appear, in legible lettering, the manufacturer's name or trademark, the model number, a serial number and the seal or mark of the testing agency. A label also shall include the following:
  1. Electrical appliances. Electrical rating in volts, amperes and motor phase; identification of individual electrical components in volts, amperes or watts and motor phase; and in Btu/h (W) output and required clearances.
  2. Absorption units. Hourly rating in Btu/h (W), minimum hourly rating for units having step or automatic modulating controls, type of fuel, type of refrigerant, cooling capacity in Btu/h (W) and required clearances.
  3. Fuel-burning units. Hourly rating in Btu/h (W), type of fuel approved for use with the appliance and required clearances.
  4. Electric comfort-heating appliances. The electric rating in volts, amperes and phase; Btu/h (W) output rating; individual marking for each electrical component in amperes or watts, volts and phase; and required clearances from combustibles.
  5. Maintenance instructions. Required regular maintenance actions and title or publication number for the operation and maintenance manual for that particular model and type of product.

Related Code Sections


Section M1303 General Mechanical System Requirements, Labeling of Appliances
A permanent factory-applied nameplate(s) shall be affixed to appliances on which shall appear, in legible lettering, the manufacturer's name ...
Residential Code 2015 of Utah > 13 General Mechanical System Requirements > M1303 Labeling of Appliances
Section M1504 Exhaust Systems, Installation of Microwave Ovens
The installation of a listed and labeled cooking appliance or microwave oven over a listed and labeled cooking appliance shall conform ...
Residential Code 2015 of Utah > 15 Exhaust Systems > M1504 Installation of Microwave Ovens
M1901.1 Special Appliances, Equipment and Systems, Clearances
material. Reduced clearances are permitted in accordance with the listing and labeling of the range hoods or appliances . The installation ...
Residential Code 2015 of Utah > 19 Special Appliances, Equipment and Systems > M1901 Ranges and Ovens > M1901.1 Clearances
M1801.1 Chimneys and Vents, Venting Required
Fuel-burning appliances shall be vented to the outdoors in accordance with their listing and label and manufacturer's installation instructions ...
Residential Code 2015 of Utah > 18 Chimneys and Vents > M1801 General > M1801.1 Venting Required
301.4 General Regulations, Labeling
An approved agency shall test a representative sample of the appliances being labeled ...
Fuel Gas Code 2015 of Utah > 3 General Regulations > 301 (IFGC) General > 301.4 Labeling
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE