E3703.2 Kitchen and Dining Area Receptacles
Go To Full Code Chapter
A minimum of two 20-ampere-rated branch circuits shall be provided for all receptacle outlets specified by Section E3901.3. [210.11(C)(1)]
Exception: Additional receptacle outlets for specific appliances shall be permitted to be supplied from an individual branch circuit rated 15 amperes or greater. [210.52(B)(1) Exception No. 2]
Related Code Sections
E3703.2 Branch Circuit and Feeder Requirements, Kitchen and Dining Area Receptacles
A minimum of two 20-ampere-rated branch circuits shall be provided for all receptacle outlets specified by Section E3901.3. [210.11(C)(1 ...
(D) Special Occupancies, General Appliances
be not over 50 percent of the circuit rating if lighting outlets (receptacles, other than kitchen, dining area, and laundry, considered as lighting outlets ...
(1) Wiring and Protection, Receptacle Outlets Served
In the kitchen, pantry, breakfast room, dining room, or similar area of a dwelling unit, the two or more 20-ampere small-appliance branch circuits ...
Section E3901 Power and Lighting Distribution, Receptacle Outlets
)]
In kitchens pantries, breakfast rooms, dining rooms and similar areas of dwelling units, receptacle outlets for countertop and work ...