• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

407.4.7.2 Keypads

2010 ADA Standards > 4 Accessible Routes > 407 Elevators > 407.4 Elevator Car Requirements > 407.4.7 Designations and Indicators of Car Controls > 407.4.7.2 Keypads
JUMP TO FULL CODE CHAPTER
Keypads shall be identified by characters complying with 703.5 and shall be centered on the corresponding keypad button.  The number five key shall have a single raised dot.  The dot shall be 0.118 inch (3 mm) to 0.120 inch (3.05 mm) base diameter and in other aspects comply with Table 703.3.1.

Related Code Sections


407.2.1.6 Accessible Routes, Keypads
Where keypads are provided, keypads shall be in a standard telephone keypad arrangement and shall comply with 407.4.7.2 ...
2010 ADA Standards > 4 Accessible Routes > 407 Elevators > 407.2 Elevator Landing Requirements > 407.2.1 Call Controls > 407.2.1.6 Keypads
707.6.2 Communication Elements and Features, Numeric Keys
Numeric keys shall be arranged in a 12-key ascending or descending telephone keypad layout. The number five key shall be tactilely distinct from ...
2010 ADA Standards > 7 Communication Elements and Features > 707 Automatic Teller Machines and Fare Machines > 707.6 Input > 707.6.2 Numeric Keys
408.2.1 Accessible Routes, Call Buttons
Elevator call buttons and keypads shall comply with 407.2.1 ...
2010 ADA Standards > 4 Accessible Routes > 408 Limited-Use / Limited-Application Elevators > 408.2 Elevator Landings > 408.2.1 Call Buttons
704.4.1 Communication Elements and Features, Height
When in use, the touch surface of TTY keypads shall be 34 inches (865 mm) minimum above the finish floor. EXCEPTION : Where seats are provided ...
2010 ADA Standards > 7 Communication Elements and Features > 704 Telephones > 704.4 TTYs > 704.4.1 Height
408.2 Accessible Routes, Elevator Landings
Elevator call buttons and keypads shall comply with 407.2.1 ...
2010 ADA Standards > 4 Accessible Routes > 408 Limited-Use / Limited-Application Elevators > 408.2 Elevator Landings
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE