[NY] Section 922 Kerosene and Oil-Fired Stoves and Heaters
JUMP TO FULL CODE CHAPTER
Kerosene and oil-fired stoves shall be listed and labeled and shall be installed in accordance with the conditions of the listing and the manufacturer's instructions. Kerosene and oil-fired stoves shall comply with NFPA 31 and UL 896.
Unvented portable kerosene-fired heaters tested and listed in accordance with UL 647 are approved by the Secretary of State for use in New York State if packaged for sale with all provisions required in New York State Real Property Law Article 7A Section 239-a(7). Unvented portable kerosene-fired heaters shall not be located in, or obtain combustion air from, any of the following rooms or spaces: sleeping rooms, bathrooms, toilet rooms, or storage closets. Portable kerosene heaters shall be prohibited in buildings of occupancy groups A, E, I, R-1, R-2, R-3 and R-4 (except for one- and two-family homes and townhouses). The use of unvented portable kerosenefired heaters is further regulated by New York State Real Property Law Article 7A.
Related Code Sections
Section M1416 Heating and Cooling Equipment, Kerosene and Oil-Fired Stoves and Heaters
Kerosene and oil-fired stoves and portable kerosene heaters shall be listed and labeled, and shall be installed or used in accordance ...
2010 Residential Code of NY > 14 Heating and Cooling Equipment > M1416 Kerosene and Oil-Fired Stoves and Heaters
Section 922 Specific Appliances, Kerosene and Oil-Fired Stoves and Heaters
and the manufacturer's installation instructions. Kerosene and oil-fired stoves and portable kerosene heaters shall comply with NFPA 31. Oil-fired stoves shall be tested ...
Section 922 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment, Kerosene and Oil-Fired Stoves and Heaters
Kerosene and oil-fired stoves shall be listed and labeled and shall be installed in accordance with the conditions of the listing ...
2020 Mechanical Code of NYS > 9 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment > 922 Kerosene and Oil-Fired Stoves and Heaters
922.2 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment, Approved Portable Kerosene Heater
Unvented portable kerosene-fired heaters tested and listed in accordance with UL 647 are approved by the Secretary of State for use in New York ...
2020 Mechanical Code of NYS > 9 Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment > 922 Kerosene and Oil-Fired Stoves and Heaters > 922.2 Approved Portable Kerosene Heater