Joists under parallel bearing partitions shall be of adequate size to support the load. Double joists, sized to adequately support the load, that are separated to permit the installation of piping or vents shall be full-depth solid blocked with lumber not less than 2 inches (51 mm) in nominal thickness spaced not more than 4 feet (1219 mm) on center. Bearing partitions perpendicular to joists shall not be offset from supporting girders, walls or partitions more than the joist depth unless such joists are of sufficient size to carry the additional load.
Upcodes Diagrams

Related Code Sections

R502.4 Floors, Joists Under Bearing Partitions
Joists under parallel bearing partitions shall be of adequate size to support the load. Double joists, sized to adequately support the load ...
2308.4.5 Wood, Joists Supporting Bearing Partitions
Bearing partitions parallel to joists shall be supported on beams, girders, doubled joists, walls or other bearing partitions. Bearing partitions ...
R606.6.3.1 Wall Construction, Joist Bearing
Joists shall have a bearing of not less than 11/2 inches (38 mm), except as provided in Section R606.6.3, and shall be supported in accordance ...