• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

2308.4.5 Joists Supporting Bearing Partitions

Los Angeles Building Code > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.4 Floor Framing > 2308.4.5 Joists Supporting Bearing Partitions
JUMP TO FULL CODE CHAPTER
Bearing partitions parallel to joists shall be supported on beams, girders, doubled joists, walls or other bearing partitions. Bearing partitions perpendicular to joists shall not be offset from supporting girders, walls or partitions more than the joist depth unless such joists are of sufficient size to carry the additional load.

Related Code Sections


2308.4.5 Wood, Joists Supporting Bearing Partitions
Bearing partitions parallel to joists shall be supported on beams, girders, doubled joists, walls or other bearing partitions. Bearing partitions ...
Los Angeles Building Code > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.4 Floor Framing > 2308.4.5 Joists Supporting Bearing Partitions
2308.4.5 Wood, Joists Supporting Bearing Partitions
Bearing partitions parallel to joists shall be supported on beams, girders, doubled joists, walls or other bearing partitions. Bearing partitions ...
Los Angeles Building Code > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.4 Floor Framing > 2308.4.5 Joists Supporting Bearing Partitions
R502.4 Floors, Joists Under Bearing Partitions
Joists under parallel bearing partitions shall be of adequate size to support the load. Double joists, sized to adequately support the load ...
Los Angeles Residential Code > 5 Floors > R502 Wood Floor Framing > R502.4 Joists Under Bearing Partitions
R502.4 Floors, Joists Under Bearing Partitions
Joists under parallel bearing partitions shall be of adequate size to support the load. Double joists, sized to adequately support the load ...
Los Angeles Residential Code > 5 Floors > R502 Wood Floor Framing > R502.4 Joists Under Bearing Partitions
R802.5.2.1 Roof-Ceiling Construction, Ceiling Joists Lapped
Ends of ceiling joists shall be lapped not less than 3 inches (76 mm) or butted over bearing partitions or beams and toenailed to the bearing member ...
Los Angeles Residential Code > 8 Roof-Ceiling Construction > R802 Wood Roof Framing > R802.5 Ceiling Joists > R802.5.2 Ceiling Joist and Rafter Connections > R802.5.2.1 Ceiling Joists Lapped
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE